@zoomuno You dont have to run it 24/7. I dont. However if you really only use the heating very sparingly then I think perhaps and air to air heat pump...
@goody I can only assume you had a terrible install? My heat pump is much cheaper to run than the gas combi I had previously and my house isnt very we...
@alfapat So the problems you have are that your house has a large heat loss (Im assuming it is a big house), your system was designed to run at a h...
@alfapat so buffer tanks act as a big roundabout for the water. Flow comes in from the heat pump and back and water goes to the heating circuit and ba...
@alfapat OK. thanks for the information. It looks like your system was designed to run at 50C when at -4C outside. The yearly electricity use for s...
@alfapat Sorry, missed the (large) tank comment 🙂 OK if the original install was for 25 kW then the 16 kW alone probably isnt oversized, but it su...
@alfapat Thats the document! unfortunately I cant read it from the images, they are probably compressed for the forum. I will pm you my email address,...
@alfapat So you should have been given the heat loss calculation when you had the heat pump installed. It has to be done by the installer. I think t...
@johnnyb So here is a day where I was cycling although not frequently The interesting bits are just as the heat pumps starts up again. Flow temper...
@johnnyb If its PWM controlled you should have two cables running to it, one for power and the other for the optional PWM control. Not all pumps can d...
@mike-h @johnnyb @technogeek So my pump is PWM controlled from the control box, but I dont know if the thermostat controller influences that at all....
@alfapat So thats a big bill! I cant help thinking that given the insulation you describe, you should be doing a lot better. Can you find your suppose...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 403 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@majordennisbloodnok Over the years, we have employed v...
By Toodles , 28 minutes ago
-
RE: Ecodan Energy Monitoring Pack
Even large pumps can be on 16 amps single phase, so the...
By Batpred , 44 minutes ago
-
RE: Heat loss calculations and how they work in conjunction with heat pump sizing
Well, in my friends case, I don't know what happened at...
By Batpred , 1 hour ago
-
-
RE: PV Panels on roof in Conservation Area
I also live in a conservation area in Derbyshire. I sim...
By Morgan , 3 hours ago
-
RE: Isolating the system for a planned power cut
I really appreciate you doing this! Solis initially pro...
By Batpred , 11 hours ago
-
RE: Renewables & Heat Pumps in the News
@batpred And RE seems to be pushing to reign in the c...
By Lucia , 12 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Yup, when I calculated how long it would take, I though...
By Batpred , 15 hours ago
-
Yes, I did mean graduates, but not just in physics. Q...
By Transparent , 15 hours ago
-
RE: Radiator sizing for heat pump installation by British Gas - are these correct?
You are spot on. I don't know TBH as I don't have ...
By JamesPa , 19 hours ago
-
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂
@editor Just had my first defrost of this season. ...
By Mike Patrick , 22 hours ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
That will be producing significant losses due to phase ...
By Transparent , 2 days ago
-
Which tells us something (including possibly everything...
By cathodeRay , 2 days ago
-
RE: Flexi-Orb Heat Pump Scheme Update: Progress, Pilots and Why This Matters for Homeowners
Thanks for sharing. Sounds promising, ISO are indepe...
By Batpred , 2 days ago
-
RE: Specifying batteries, pv solar etc using ChatGPT
I have been positively surprised when I asked it to spe...
By Batpred , 2 days ago