@alfapat I think modern TRVs can be fitted on either side. The lock shield will restrict flow whichever side it is sited
@alfapat Remember Pat, as the outside temperature varies, so does your flow temperature. If you are not getting to room temperature today when its war...
@alfapat yes if you can get the maximum flow temp to 46C from 50C that will be a result. you will find that each adjustment will affect every other...
@alfapat that is what water law is for Pat. It automatically adjusts the flow temperature to take into account the OAT. Once you have the rad valves r...
@chandykris just give them a good wash out before fitting them back 😁
@wawyed Thats the only thing I could think of that might account for the difference. It looks odd but I doubt its affecting COP much
@chandykris Yes, I did that, just bought two big radiators and shifted the others into different rooms. No problems.
@wawyed Mine isnt doing that, is your water pump PWM controlled?
@johnnyb Is that different to what Toodles has shown in the response above?
@toodles Thanks, thats actually more than I expected so quite useful.
@alfapat So this is the lockshield valve Sometimes they have knurled knobs on which can be used to adjust them, but if not then just use a smal...
@alfapat Sorry, I didnt see the temperature readings. So you are losing about 4C by using the buffer which I think is about an 8% loss in efficiency. ...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 127 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Isolating the system for a planned power cut
I really appreciate you doing this! Solis initially pro...
By Batpred , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
@batpred And RE seems to be pushing to reign in the c...
By Lucia , 5 hours ago
-
RE: Heat loss calculations and how they work in conjunction with heat pump sizing
Great, you did the right thing! I am not clear if you r...
By Batpred , 6 hours ago
-
RE: Say hello and introduce yourself
Welcome. Do feel free to start a new thread about your...
By JamesPa , 6 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Yup, when I calculated how long it would take, I though...
By Batpred , 8 hours ago
-
Yes, I did mean graduates, but not just in physics. Q...
By Transparent , 9 hours ago
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@editor We defiantly need to come up with a way a custo...
By ASHP-BOBBA , 12 hours ago
-
RE: Radiator sizing for heat pump installation by British Gas - are these correct?
You are spot on. I don't know TBH as I don't have ...
By JamesPa , 13 hours ago
-
PV Panels on roof in Conservation Area
The house is on a boundary of, but inside, a Conservati...
By colinc , 13 hours ago
-
RE: Ecodan Energy Monitoring Pack
Interesting. I tried very hard to monitor energy consum...
By Carpenterstation , 16 hours ago
-
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂
@editor Just had my first defrost of this season. ...
By Mike Patrick , 16 hours ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
That will be producing significant losses due to phase ...
By Transparent , 1 day ago
-
Which tells us something (including possibly everything...
By cathodeRay , 1 day ago
-
RE: Flexi-Orb Heat Pump Scheme Update: Progress, Pilots and Why This Matters for Homeowners
Thanks for sharing. Sounds promising, ISO are indepe...
By Batpred , 2 days ago
-
RE: Specifying batteries, pv solar etc using ChatGPT
I have been positively surprised when I asked it to spe...
By Batpred , 2 days ago