Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 3, 2025
We have 4 on ours. 1 on flow, 1 on return (due to long outdoors pipe run they didn’t oversize…) central heating UFH
We set out pumps to be controlled by the ASHP rather than the stats and had the same concerns as you. Eg if on WC would the pumps just run 24/7? ...
What are you trying to achieve? My understanding is you’re best not interfering with the HPs controls. we’ve just changed ours and ripped out...
@derek-m Thanks for the info. And yes understood. What I’ve observered though, which was not expected, is that if you have the official Mitsi r...
Something I have noticed since installing the official Ecodan remote controller is that when in WC mode, it will still turn the HP off if the target r...
Yes I’m unsure of the room adapt mode. Mitsubishi seem to push it as the best option but who knows. Agreed it may ramp up quite a bit from cold. Wi...
Normally UFH has its own stats and that calls the HP for heat. So it doesn’t work in reverse, turning up the heating in the Ecodan won’t force the UFH...
That’s our winter load so very little PV at that time. in the summer we only pull about 15kWh from the grid without batteries due to evening mea...
Yes to be honest when it was 11p/11p that was our main reason for wanting a Powerwall. Running the ASHP at 11p wouod be amazing Now it’s 26p the...
Just posted a W on this. If using Weather comp, what to do overnight? serms a clash between it being colder outdoors, so flow temp goes up. But ...
- 27 Forums
- 2,768 Topics
- 65.2 K Posts
- 1,357 Online
- 7,170 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why are ASHP installs so expensive?
And yet we almost all of us do exactly that when buying...
By Majordennisbloodnok , 7 minutes ago
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 17 hours ago
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 22 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
The Heat geek contract had various get-out clauses with...
By Batpred , 24 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 1 day ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 1 day ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 1 day ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 2 days ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 2 days ago
-
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 3 days ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 4 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 5 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 5 days ago