Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 3, 2025
Tweaked the weather comp settings removed all the Tado room stats and UFH zones so it’s just one big zone now balanced the radiators i have ...
Lower flow temps help avoid defrosts I think! Can you run for longer at lower flow temp?
We made £7.57 (91% reduction in usage). Impressed with that.
Sounds like the universe gave you a nudge! im sure it’ll be fine.
it was running at about 33c before I turned it down. After an hour it turned it back on and it climbed to 38c for 2 hours then back to 36c But a...
We got down to 170w when we turned everything off. It seems the WiFi router and CCTV take up quite a bit! The temperature in the house only shifted ...
Thanks all. I will do some measurements and also try opening some valves i did try turning the pump down from 3 to 1 but the delta didn’t shi...
I’ll be turning mine down yes it could cost a bit more the following hour (and ours is in room adapt so it’ll adjust flow temp upwards slightly)...
@derek-m Thanks Derek Were in Weather Comp mode. 45c @-2, 25c @ 12c This has been fine, but I have bumped it up +4 this week with it being w...
- 26 Forums
- 2,631 Topics
- 61.5 K Posts
- 373 Online
- 7,028 Members
Join Us!
Latest Posts
-
RE: Anyone concerned about GivEnergy?
@editor Thank you for your reply. We do have an active ...
By SUNNYSKIES , 6 minutes ago
-
RE: Estimating true heat loss from twelve months of consumption data
@ian33a — a measured heat loss always trumps a calculat...
By cathodeRay , 48 minutes ago
-
RE: Setback savings - fact or fiction?
@cathoderay Thanks for your detailed response.Just two ...
By PeterWurmsdobler , 56 minutes ago
-
RE: Grant Aeona 3 R32 cycling with weather compensation.
The hot water heating looks normal. The heat transfer ...
By GrahamF , 3 hours ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
Good questions @temperature_gradient. My understanding ...
By springswood , 5 hours ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
All going according to plan, mid July we get that 7kW a...
By Batpred , 16 hours ago
-
Current metrics - DHW target set to 47c
By TaffontheTaff , 21 hours ago
-
RE: My Grant R290 9kW Heat Pump Installation
@petch I'm very sorry that I have not picked up your po...
By GrahamF , 23 hours ago
-
RE: Samsung gen 7 HP 12kw - auto control issue and water law
Suggest you have a trial with Havenwise app. I have th...
By Broadsman , 1 day ago
-
RE: New Solar, Batteries, Air Source and Under Floor Heating advice please
You’re right: UFH works best with high-conductivity fin...
By bafab , 1 day ago
-
RE: DIY or Don’t Touch? Solarman Smart Meter Install
That was my understanding also.
By JamesPa , 1 day ago
-
RE: Vaillant Sensocomfort Time
Oh I remember this from when I set mine up 2 years ago,...
By JamesPa , 2 days ago
-
Heat geek have already stated that the pro is in fact c...
By JamesPa , 2 days ago
-
RE: The Myth of the MCS Performance Guarantee
@editor I know. As if MCS wasn't bad enough, it's now e...
By Deltona , 2 days ago