Last seen: Nov 16, 2025
I think the NIBE uses both the ASHP and the element to reach the desired temperature, you need to make sure the element portion is working, you could ...
If they have used the wrong antifreeze you would want it taken out, if they used one of the 3 most popular monopropylene glycol's they can likely be m...
This is what is used in nearly all ASHP system that have glycol.
@jamespa anytime. you would not believe how many times I have had to stop myself going so far as to write a complete document to a solution, I keep re...
@cathoderay Unfortunately, you are correct and although there are many sound ways to work this out manually and roughly, to balance systems correctly ...
@jamespa hi James, yep in deed you can and thet would be my 1st solution rather than change a rad but it does effect the overall flow of the system sl...
@andrewj Oh, thats a good one, so the answer is subject to what power and recovery you have for the room/s assuming its typicly balanced and has the c...
@andrewj Ah, maybe, they also often design to 50 Deg C flow rate and do everything to reduce the amount of emitters changed. If you balance everything...
@andrewj so this thermostat would normally go in a room that would be considered an average comfort, this stat is also only used to feed some info bac...
📈 Role of the Internal Stat (Thermostat) When the internal stat is active while using a weather curve, it modulates or overrides the weather ...
this is the actual answer to yur question and they both aim to provide the same thing and are related, this means both effect the other in some form. ...
@johnmo I have just seen that Mars has uploaded another podcast titled to your question, I more or less answered but I have not watched this cast yet,...
- 26 Forums
- 2,323 Topics
- 52.1 K Posts
- 294 Online
- 5,979 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
No need to change anything, just to capture current val...
By JamesPa , 16 minutes ago
-
This is what I answered, I really have no hope: "......
By Batpred , 2 hours ago
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@andrewj oh yes they offer Daikin 8kW, they tried to fo...
By AgentGeorge , 3 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@majordennisbloodnok Good point! Just in case anyone re...
By Batpred , 4 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira
After calling octopus they suggested that it would cost...
By stevettweed , 4 hours ago
-
RE: Hitachi Yutaki SCombi Heat Pump - Owners
@sim0n0 It would be very useful if you could tell us...
By trebor12345 , 4 hours ago
-
RE: Electricity price predictions
Good to know @transparent What do you think reform w...
By Jeff , 4 hours ago
-
RE: Benefits of an extra horizontal loop for GSHP
A correct sized collector is all you need. Saying this,...
By greenlight , 6 hours ago
-
RE: Grant Aerona Short Cycling
@mikefl, thanks for sharing your operating data, very i...
By Steam Powered , 7 hours ago
-
-
@f1p, sorted, on a android phone Just swaped from ...
By @sand , 11 hours ago
-
RE: Here is my heat pump installation with questionable COP in Italy
@jamespa Sorry for the late reply, I apologize for the ...
By materox345 , 12 hours ago
-
RE: Trying to understand my Nibe F1245
First of all you have one of the best geothermal heat p...
By greenlight , 12 hours ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
@editor Yes BUT that was 3 years ago installed in Janua...
By rob heatpump bob , 23 hours ago
-
Thanks for your response. I have UFH downstairs and ...
By GeorgeA , 24 hours ago
-
RE: Home energy storage & battery register
2 days uninterruptible power supply (at the moment) wit...
By Batpred , 1 day ago
-
We have a Vaillant aerotherm with sensocomfort. We have...
By Newbie , 1 day ago
-
@trebor12345 Yes, expect defrost cycles to initiate at ...
By IaAck , 1 day ago
-
I would probably have them in white as that would match...