Hitachi Yutaki SCombi Heat Pump(Indoor Unit ) RWD-3.0RW1E-220S-K(Outdoor Unit) RAS-3WHVRP1 2024 build bungalow200m2High level of insulationUnderfloo...
@robs On the 5. 10kW Viessmann Vitocal in Sheffield. What is causing the heat pump to turn off and on every hour (approx). It it a room thermostat o...
Thanks for your help.
I have no idea, to me there is no logic. There is no information on-line about this Hitachi system, so a bit of a loss.
The heat generated in the 5 minute period is with the pump on which goes to the manifold and floor. My de-ice cycle is exactly as yours.
In the 5 minute period the compressor is running, taking electrical power and producing heat. This, what Hitachi call a "Thermal Off" I might call a ...
The first dip is the thermal off period where the compressor stops for 3 minutes and the refrigerant in the pipe from the heat pump to the internal un...
The fan does turn off, water from inside is then pumped in reverse, power is take to heat the water and then the fan and compressor runs. Takes about...
@editor I just wanted to know other owners thoughts and experience of this system. I am having issues with short cycles and getting steady flow tempe...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 36 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Inventor (Midea) Heat Pump short cycling advice
I installed the 80L tank (volumizer) things got better ...
By immunity , 1 hour ago
-
RE: Mitsubishi Ecodan F8 error
I absolutely love this. This is the quintessential heat...
By Mars , 8 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@papahuhu at the end of the day if you are happy with h...
By benson , 13 hours ago
-
RE: Can you recommend a Mitsubishi service engineer in the Rochdale area?
@dgclimatecontrol We'll all need annual servicing. How...
By Suzy-shadow , 13 hours ago
-
RE: Renewables & Heat Pumps in the News
@transparent I’ve understood your point now. The point ...
By Judith , 14 hours ago
-
RE: Octopus tariffs - a quick comparison
Does indeed need checking, @tim441. Neither Homely ...
By Majordennisbloodnok , 14 hours ago
-
RE: How not to install a heat pump
Delighted to hear that the buffer has been replumbed as...
By JamesPa , 15 hours ago
-
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
Yes but 9kW is similarly the 16kW derated. So 8kW subs...
By JamesPa , 17 hours ago
-
Actually, there's a rather greater degree of cattle-her...
By Majordennisbloodnok , 17 hours ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@davidnolan22 So far as I can tell from the 'other p...
By JamesPa , 21 hours ago
-
RE: 5 Star Service from Havenwise
I keep getting havenwise ads on my Facebook feed, so cl...
By benson , 23 hours ago
-
Automation options to maximuse efficiency & ToU tariffs
I started a conversation with ChatGPT. What automation...
By Tim441 , 1 day ago
-
RE: 4 Year Ongoing Heat Pump Battle With Poor Heat Pump Installation
@jamespa Oh, I know some that are good and some not so....
By ASHP-BOBBA , 1 day ago
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
I don't know how many pumps you have but I guess it's o...
By JamesPa , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
That's just human nature unfortunately, not special to ...
By JamesPa , 1 day ago
-
@bontwoody how long has it been now since you started t...
By Mars , 2 days ago
-
RE: Bosch CS5800i 5kW - Experience So Far
Yes, over the last few days I've been keeping a very cl...
By Steelbadger , 2 days ago
-
Absolutely. I am one of those members and I most certai...
By Majordennisbloodnok , 2 days ago