Last seen: Nov 2, 2025
OK. So the problem stems from your Energy Supplier not giving you the raw consumption figures.You are only presented with the kWh figures after they m...
It should be possible to verify your gas bill by using a 'rolling' spreadsheet.You'd have to insert formulae that apply adjustments after noon the...
Ah... that would be defined as V2H (Vehicle to Home) or V2G (Vehicle to Grid) @toodles In either case you'd require G98 approval for the inverter, G...
@david999 - I think that @derek-m is about to address that point.and he'll make a better job of it than I will. The principle is that you don't hav...
To derive a gas bill in kWh from the meter readings in m³ (cubic metres) x 1.02264 (volumetric correction - a constant, based on barometric pressur...
Yes. The only route to communicate commands to a Smart Meter and receive data from its registers is via DCC.All communications paths in/out of DCC are...
I think that's Miliband, rather than Milligan @editor 😊 And for those who don't know, he's Shadow Minister for Energy Security & Net Z...
Why would a sensor for external air temperature be placed in the airflow being drawn through the fins? Placing it within a sleeve might provide mech...
I think we need to consider the charging schedule against a wider range of inputs than those commonly used within HA. The present EV Charging legisl...
I can't find that exclusion clause in the Consumer Rights Act! That's only 5 months ago, anyway.That doesn't sound an abnormally long interval befor...
The 'banding' can be read as a bar-code which describes how well the defrost cycle is operating 🤔 Was the cavity insulation work ...
Oh dear, oh dear!Let's take this one point at a time. 1: Are you saying that they drilled 22mm holes vertically through the (suspended) concrete...
- 26 Forums
- 2,262 Topics
- 50.5 K Posts
- 333 Online
- 5,922 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: What valves to replace radbots?
Yes. Radbots just replace TRV heads. TRV heads push t...
By JamesPa , 2 hours ago
-
RE: Who has a V2G EV installation
Im looking at Anderson or Simpson and Partners, somethi...
By AgentGeorge , 3 hours ago
-
RE: When will fusion be producing energy?
I am thinking of the case where AI was able to distingu...
By Batpred , 13 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@agentgeorge Where there’s muck … 😉 Toodles.
By Toodles , 17 hours ago
-
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
@majordennisbloodnok Thanks for the welcome and yes I...
By Mark Nelson , 18 hours ago
-
So after playing about with DHW settings for a while I ...
By bontwoody , 19 hours ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
I’ve got 5.4kW array, 9.6kWh battery, 5kW heat pump, EV...
By Gruff2001 , 22 hours ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Very definitely. I think the market has changed a bit...
By JamesPa , 23 hours ago
-
RE: Buying large amp bidirectional RCD and RCBO
The following diagram is taken from the Meter Operator'...
By Transparent , 1 day ago
-
RE: British Gas Heat Pump Installation Complaint
@steelbadger That's great to know! Thanks for that reas...
By BGNO , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@allyfish It was going so well with month after month s...
By Toodles , 2 days ago
-
RE: Electricity price predictions
As that's an energy issue, it would need the DESNZ to p...
By Transparent , 2 days ago
-
RE: UFH downstairs and radiators upstairs balancing question
Have you tried turning up the stat and turning down the...
By JamesPa , 2 days ago
-
-
RE: Mediation with RECC, what's your experience?
Welcome to the forums @treewizard and sorry to hear abo...
By Mars , 2 days ago
-
RE: New build installation query
That accounts for why you start with an overly-high DHW...
By Transparent , 2 days ago
-
RE: Daikin Altherma 3 / HomeAssistant
I would have thought that (instantaneous) power is a fa...
By JamesPa , 2 days ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
Alright, I concede that the Toyotas are, as you say a v...
By JamesPa , 2 days ago
-
RE: Is it mad to think there should be a minimum SCOP for UK heat pump installs?
Sadly I think it is mad. If the BUS is not granted for ...
By Judith , 3 days ago