Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 17, 2025
I have direct experience of this. When a high temp pump was put in to replace a low temp one in my rented accommodation running costs significantly in...
@derek-m It's in the hallway. I do have the Sensocomfort set to weather compensation (after months of persistence) but unfortunately many other issues...
@sapper117 I don't have any PV panels sadly. I'm trying to find ways of maximising efficiency in the Winter months even though the Summer months shou...
@bretix This is what it says in the installation manual for your pump..... '3.5.3 CONDENSE DISPOSALThe underside of the heat pump has a condensate ...
@derek-m Yes, I have a portable thermostat though for my UFH (which generally stays in the lounge with me). Vaillant have a specific weather compensat...
@morgan My heat pump has some kind of heat wire going into the drain (well it will have when it is redone as at the moment it is hanging over the grou...
To make any kind of informed decision you would need a detailed heat loss calculation done by a reputable person and who preferably has no specific li...
If your path is turning into an ice rink there is likely a problem with the condensate drain which the installer should have done properly. The conden...
@webcmg Unfortunately I'm still trying to get to the bottom of all the issues here and there is a long list. It's all affected me really badly. I'm st...
I'm also trying to get to the bottom of my high running costs. It is arduous to say the least. Have you had an independent inspection @webcmg?
I think the Arotherm plus' have an option to set up an adaptive curve using a specific controller and sensors, (not available to me, of course 😏 as I ...
@hughf Sadly yes.
- 26 Forums
- 2,725 Topics
- 63.8 K Posts
- 1,188 Online
- 7,126 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Jokes and fun posts about heat pumps and renewables
@transparent I’ve heard that that is why American cars ...
By Toodles , 2 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Have either quote provided room by room heat loss calcu...
By Old_Scientist , 16 hours ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@old_scientist if you are going DIY then you may wan...
By Papahuhu , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
After a short while that was followed by the 'power war...
By JamesPa , 2 days ago
-
RE: Samsung heat pump - data cable issue
That's well done. Cable is the correct type (LIYCY = 2x...
By bobflux , 2 days ago
-
RE: Electricity price predictions
I agree, we will find out at the next budget whether th...
By Old_Scientist , 3 days ago
-
RE: Missing flow temperature in Heat Geek proposal
@editor I went through HG website, so should be ok for ...
By sttpd1917 , 3 days ago
-
Who did the Freedom Heat Pump cloud server and what did...
By Mars , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
Reading between the lines of what octopus are doing wit...
By JamesPa , 3 days ago
-
RE: Air to air bus grant installer anywhere
The through wall two hole ones have their place (listed...
By EtchedPixels , 3 days ago
-
I hope it goes ok, Hon can be hard to set up IF the sof...
By Graham Hendra , 3 days ago
-
@clockworks Hi, So there is a big difference between st...
By ASHP-BOBBA , 3 days ago
-
@editor wellvery comprehensive answer. I will get all i...
By Keithb , 3 days ago
-
RE: Advice on my Heat Pump Journey: Old Stone Built Detached Cottage
all good advice I will follow this up
By PaulC , 3 days ago
-
Heat of vaporization of water is 2.25 MJ/kg (0.625 kWh/...
By bobflux , 4 days ago