@cathoderay Apols for badgering on this topic about other controls, but do you really have just have weather compensation only running ? As I under...
[quote data-userid="5190" data-postid="19305" A volumiser in the primary, together with a good insulation of the PHX to reduce delta T to around 1C m...
@cathoderay With regard to the cycling:Exactly what controls do you have? I understand you have a manufacturers weather compensation system, and T...
A few ideas to consider: The ashp is outside - no doubt it's measuring produced power at the unit, so will include any pipe losses that the oil boil...
"Natural" gas is effectively an unlimited supply of highly flammable material - and so is super dangerous! Our R290 gshp is outside (tick!) and use...
The heat exchanger material conductivity is actually a compromise. Through the material, the thin way, we want high conductivity. Along the material...
@gutoffowc Plastic heat exchangers are usually used inside MVHR units. For an air:air heatexchanger, there's not that much heat transfer needed ac...
@iancalderbank I'd love to see MID certified meters installed under MCS, and then a guaranteed SCOP performance from it! I appreciate the meters c...
The blog on this forum compares installed SCOP to manufacturers datasheets, giving overall average of 2.7:
I think that the price ratio of Electicity to Gas is largely responsible for the UK's reluctance to embrace heatpumps. I understand that it will come...
@gutoffowc It sounds like it needs more than recalibrating. Perhaps the original installers? We have a vent axia sentinel kinetic BH plus, it ha...
Here’s an example of a mid certified meter- if you have a spare slot in your consumer unit, it’s an easy install for a sparky, split core so just clip...
- 26 Forums
- 2,306 Topics
- 51.7 K Posts
- 344 Online
- 5,970 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Commencing on an ASHP Installation Process
Me too, but I think we are in the minority. Most homeo...
By JamesPa , 1 hour ago
-
RE: Electricity price predictions
Simple article with a DENZ graph showing how gas which ...
By Jeff , 1 hour ago
-
RE: 10kw heat pump run in 24*7 data?
Thats really helpful as it clearly says target 49C. So...
By JamesPa , 1 hour ago
-
Power Cut - Heat Pump Evaporator Iced Up
We have just had a power cut and 1 hour later power was...
By trebor12345 , 2 hours ago
-
RE: Buffer tank bypass on EDF Ideal heat pump installation
Well I can try the valving which can be undone so I don...
By KevB , 4 hours ago
-
@sand Yes. The COP is reported and you can split it int...
By bontwoody , 4 hours ago
-
RE: Why Millions of UK Homes Struggle With Heat Pumps
A few weeks ago, I was having a discussion with someone...
By Majordennisbloodnok , 5 hours ago
-
RE: Don’t Install a Heat Pump Until You Read This
@davidnolan22 Inspired by someone on buildhub I asked C...
By JamesPa , 5 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk Hi I see you posted on openenergymon...
By JamesPa , 7 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Often the default password is in the installation manua...
By JamesPa , 7 hours ago
-
RE: Cashback Incentives That Reward Shorter Heat Pump Warranties
@andrewj Indeed, ’Appalling’ is a rather mild term for ...
By Toodles , 7 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira
@editor When do “Mars Heat Pump Installation and Servic...
By Toodles , 8 hours ago
-
@morgan Likewise, I realise that some readers will appr...
By Toodles , 8 hours ago
-
A Smarter Smart Controller from Homely?
I received an email from Homely this morning enquiring ...
By Toodles , 9 hours ago
-
RE: Grant Aerona 3 and Drayton system questions
Yes in general terms (obviously I cant tell if its exac...
By JamesPa , 11 hours ago
-
Yes, the Grundfos pump has a built in timer. However, t...
By DavidAlgarve , 12 hours ago
-
RE: Heat Pump on Flat Roof Low Frequency Noise from Detached Neighbor
1) talk to your neighbour, that's unacceptable noise, a...
By davidnolan22 , 13 hours ago
-
Ecodan - Flow temperature spiking causing shutdown
Hi everyone, looking for some help. I am in a new bu...
By Gl3484 , 1 day ago
-
Solis AI is on the right track to leverage the battery:...
By Batpred , 1 day ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Thanks James, its honestly hard to keep it tog...
By Crimson , 1 day ago