I can't think of a single reason why you would want to operate a counterflow heat exchanger the wrong way around, the inefficient parallel way, in a h...
@transparent I'm "listening" eagerly to this thread too! We have old 4kWp FIT PV with an MCS form, and I now have dno approval for an additional, ...
@cathoderay Apols for badgering on this topic about other controls, but do you really have just have weather compensation only running ? As I under...
[quote data-userid="5190" data-postid="19305" A volumiser in the primary, together with a good insulation of the PHX to reduce delta T to around 1C m...
@cathoderay With regard to the cycling:Exactly what controls do you have? I understand you have a manufacturers weather compensation system, and T...
A few ideas to consider: The ashp is outside - no doubt it's measuring produced power at the unit, so will include any pipe losses that the oil boil...
"Natural" gas is effectively an unlimited supply of highly flammable material - and so is super dangerous! Our R290 gshp is outside (tick!) and use...
The heat exchanger material conductivity is actually a compromise. Through the material, the thin way, we want high conductivity. Along the material...
@gutoffowc Plastic heat exchangers are usually used inside MVHR units. For an air:air heatexchanger, there's not that much heat transfer needed ac...
@iancalderbank I'd love to see MID certified meters installed under MCS, and then a guaranteed SCOP performance from it! I appreciate the meters c...
The blog on this forum compares installed SCOP to manufacturers datasheets, giving overall average of 2.7:
I think that the price ratio of Electicity to Gas is largely responsible for the UK's reluctance to embrace heatpumps. I understand that it will come...
- 26 Forums
- 2,360 Topics
- 53.5 K Posts
- 328 Online
- 6,026 Members
Join Us!
Worth Watching
Latest Posts
-
RE: New Fogstar 15.5kWh upright solution
@transparent I have 3 of these units and ex...
By Bash , 39 seconds ago
-
I also enjoy the challenge of getting the best out of s...
By downfield , 4 minutes ago
-
When checking the Met Office website to see what weathe...
By Toodles , 8 minutes ago
-
RE: Speedcomfort radiator fans
&mars SpeedComfort have confirmed my understanding ...
By Richard24738 , 22 minutes ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Hi @mickamills . Welcome to the forum. It sounds like...
By bontwoody , 34 minutes ago
-
RE: External pipework insulation
@transparent I hope you are not being admonished @trans...
By Toodles , 42 minutes ago
-
RE: Setback savings - fact or fiction?
Oops, well spotted, thanks. Yes they are the wrong way ...
By cathodeRay , 60 minutes ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@gruff2001 Our Growatt 13 kWh system charges about 11.7...
By ChandyKris , 1 hour ago
-
RE: Mitsubishi Ecodan R290 10kW performance
All noted, Im not doubting you, just trying to be certa...
By JamesPa , 5 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 22 hours ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 22 hours ago
-
RE: Midea ASHP – how to set weather compensation
@pash44pump I have yet to come across any Clivet or Mid...
By benson , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 1 day ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 1 day ago
-
-
RE: Advice on internal circulation pump noise
Extend the primary branch and make sure you have more t...
By ASHP-BOBBA , 2 days ago
-
RE: Jokes and fun posts about heat pumps and renewables
By Morgan , 2 days ago
-
RE: Controlling Daikin Altherma via P1P2 and Home Assistant
On the contrary, @toodles, that’s a lot of help. I’d ne...
By Majordennisbloodnok , 2 days ago