Unfortunately I don't really have any experience of trying to control the unit with minimal modbus. The only thing I used on Linux was mbpoll to initi...
Thanks very much Ian, I changed FSV 2091 to "Not Use" but it didn't have any effect. I then also changed FSV 2092 External Thermostat Application #2 (...
@iancalderbank I have come back to this a number of times but always thought I was doing something wrong. My system was initially set up to use Water ...
@kocta This is my configuration.yaml code which is very much based on the work of others here # Samsung Heat Pump Modbus Connection modbus: - name...
I came across this video which is an interesting example of heat pump control within Home Assistant
I have added the UI config and the YAML config of the script here. The main part is "modbus.write_register" and the payload associated with that. As...
@derek-m I only heat the water twice a day (at the moment it's to 50 degrees from 02-05:00 during the cheap night rate and to 42 degrees from 15:45-16...
@derek-m I am on a variable tariff so I'm turning heating and hot water off from 17-19:00 and upping the hot water set temperature from 2-5:00 I'm u...
I meant to credit Glyn Hudson for the hidden registers PDF which I found on his GitHub page
I had converted the Samsung Modbus MIM-B19N section on registers from PDF into Excel just to make it a bit easier to understand for myself. The sectio...
@iancalderbank I am doing the calculations after I upload the data inputs to Emoncms.org Input = Heat Pump Shelly EM CT clamp + Indoor Tank Shelly E...
@iancalderbank I had the same thoughts when wiring up my 8kw unit. I used a few cable ties also and tried to find somewhere that made sense.
- 21 Forums
- 1,962 Topics
- 42.6 K Posts
- 70 Online
- 2,277 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@jamespa Agreed. I think it’s a case of much over muchn...
By Mars , 32 minutes ago
-
@eliuccio Unfortunately, whilst I agree with a lot of...
By JamesPa , 59 minutes ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
@bami I think if the heat loss documentation matches a ...
By bontwoody , 1 hour ago
-
RE: What is the best strategy for operating a very oversized heat pump?
@jamespa I'm afraid that's over my head but if anyon...
By IRMartini , 2 hours ago
-
RE: Setback savings - fact or fiction?
And here in case any one wants it is the code I used in...
By cathodeRay , 2 hours ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
Definitely its in the 20xx FSVs. Conversely it may be...
By JamesPa , 2 hours ago
-
RE: Towel rails. An unexpected final hurdle
We have both Normal Rad for heating the room and then a...
By IRMartini , 4 hours ago
-
RE: Heat Pump Sizing & Installation Costs
Perhaps useful to have installed date too? To get conte...
By Tim441 , 6 hours ago
-
RE: SolarPV tables / online calculator
I'd be interested what others find whilst using that we...
By Majordennisbloodnok , 8 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 20 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 23 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 1 day ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 1 day ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 1 day ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 1 day ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 1 day ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 1 day ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 2 days ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 2 days ago
Latest Topics
-
Heat Pump Sizing & Installation Costs
By Mars 8 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 9 hours ago
-
SolarPV tables / online calculator
By MichelleC 16 hours ago
-
By Toodles 2 days ago