@Derek-m [/quote] Your bills are lower, because the tariff may possibly be lower, but also because forum members helped your sort out all the issu...
@derek-m I simply have a kwh meter that just reports heat pump usage. I monitored for 24hour period running 24/7,approx 30kwh usage, most days im runn...
I doubt ye will ever be able to conclusively agree on the interpretation of the data. Could it be that yes fabric of house cools a bit but the real fe...
If desired room tmp is 20, i doubt 20degflow would achieve that, surley some losses on transfer and to get up through the slab.
Yep kinda relieved its not doing defrosts at mild temps, think every5-8hours it happens, lwt drops below rwt like a defrost, lasts maybe 1-2minutes, d...
@derek-m/p> Found this Derek, i don't really understand it. It seems to do this function, originally thought it was defrosting but OAT 10deg today a...
Its in the operation manual, the page where it tells you what the symbols mean. Also in running mode tab on my low temp split altherma2, it has defros...
hi toodles, seeing as you have daikin you might know, i was noticing frost symbol at 8deg OAT, but since i have discovered oil return function has sam...
Yes that's exactly it, even when cold though after maybe 8hours, the heat pump modulated down to 11.4l/min,approx 1/3 of capacity so energy usage drop...
During cold spell last week, i first started with setback, however the usage turned into 5/6kw per hour and house wasnt at ambient temp until late in ...
anybody with a daikin, do ye know if BUH is enabled and runs during space heating when unit is in defrost mode. So far in December mine has run for 4 ...
So was away in Scotland since Thursday and was shocked at my usage on app. Saturday morning i was pulling 7kw at 7am, seems BUH was running, is that p...
- 23 Forums
- 2,098 Topics
- 46.2 K Posts
- 39 Online
- 3,385 Members
Join Us!
Latest Posts
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 27 minutes ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 30 minutes ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 7 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
Hmm Before doing that I would want to be certain that...
By JamesPa , 12 hours ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 13 hours ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 23 hours ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 1 day ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 1 day ago
-
If you are thinking of heating on the immersion conside...
By JamesPa , 3 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness, I think your best bet would be using ...
By Aventus Eco , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles all depends on asking the right questions! And...
By Tim441 , 3 days ago
-
RE: Commencing on an ASHP Installation Process
I received confirmation this morning that my Greener Ho...
By Sheriff Fatman , 3 days ago
-
@jamespa Thanks for the advice - very helpful. I had al...
By abam48 , 4 days ago
-
RE: Adding battery storage to SolarEdge PV system
@chandykris No need to apologise at all! I forgot to ad...
By Toodles , 5 days ago