Last seen: Feb 10, 2025
They took easy option, I didn't think about noise at the time. Base up to it il do next year idsay.
Footpaths weren't in when installing so done handy option i think. It's leaning forward too which I don't like. I'm going to add weight to it first to...
Cheers, yeah that was my nuclear option to build pad up to it. Probably job for next year now. Was it poor installation?
Had thought about building up to it, that way no need to rewire or plumb. Heard putting more weight on unit could help like few 4 inch blocks.
Hi, having lot of vibration from my wall mounted heat pump. In cold weather especially it's as if whole house vibrating. Anything to help this noise a...
Latest installer suggested I could get 5 on south roof in pic2 and 4 south roof pic1 behind heatpump and 9 on west roof but Do people think the s...
Thanks for replies. The chimney wont interfere too much with the west panels as far as i can see. I wont opt for battery yet as prices coming down and...
Hi, im looking into solar for my home, I have been offered 7.8kwp array by a few installers so 18panels. I am unsure about orientating them however as...
242sqm new build, house 21/22. Nov Dec 2023 approx 1400kwh. Near 40% less then my first winter thanks to suggestions here, I'm setting back overnight ...
Seems any pipework that is leaving the room is insulated so not sure if it would make a a noticeable difference to my bills to insulate the internal p...
Very happy with advice i got here on how to optimize my heat pump. I am finished altering settings as recently finished balancing the house to my liki...
@derek-m ahh OK. Yeah it's the condenser so luckily by the sounds of things.
- 21 Forums
- 1,962 Topics
- 42.6 K Posts
- 64 Online
- 2,276 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@jamespa Agreed. I think it’s a case of much over muchn...
By Mars , 15 minutes ago
-
@eliuccio Unfortunately, whilst I agree with a lot of...
By JamesPa , 42 minutes ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
@bami I think if the heat loss documentation matches a ...
By bontwoody , 1 hour ago
-
RE: What is the best strategy for operating a very oversized heat pump?
@jamespa I'm afraid that's over my head but if anyon...
By IRMartini , 2 hours ago
-
RE: Setback savings - fact or fiction?
And here in case any one wants it is the code I used in...
By cathodeRay , 2 hours ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
Definitely its in the 20xx FSVs. Conversely it may be...
By JamesPa , 2 hours ago
-
RE: Towel rails. An unexpected final hurdle
We have both Normal Rad for heating the room and then a...
By IRMartini , 4 hours ago
-
RE: Heat Pump Sizing & Installation Costs
Perhaps useful to have installed date too? To get conte...
By Tim441 , 6 hours ago
-
RE: SolarPV tables / online calculator
I'd be interested what others find whilst using that we...
By Majordennisbloodnok , 8 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 20 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 22 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 1 day ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 1 day ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 1 day ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 1 day ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 1 day ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 1 day ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 2 days ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 2 days ago
Latest Topics
-
Heat Pump Sizing & Installation Costs
By Mars 8 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 9 hours ago
-
SolarPV tables / online calculator
By MichelleC 16 hours ago
-
By Toodles 2 days ago