I suppose that might be true at a stretch if you were doing space heating throughout the summer, but who does that? I would dig your heels in until yo...
@ashp-bobba Welcome to the forum. I would be interested to understand the reasoning behind your statements. What was your experimental set up? I would...
Can you explain the mechanism for this effect? Could it just be coincidental rather than causal? System volume may prevent short cycling, but there ar...
With your 2091/2092 settings, the heat pump will only cycle off if your 3rd party thermostat is no longer calling for heat. If your home is warm, t...
Those settings exclude frequent cycling as the cause of poor efficiency. With 2091/2092 set to 'Use(Signal only ON/OFF)', FSV 2093 is inactive, so it ...
@raiph I apologise for my incorrect assumption. A PWM pump should maintain your delta T, so I am not clear why you are experiencing problems with a lo...
@raiph You seem to want a Delta T of 5, but your water pump has a fixed speed / flow rate which is currently 15 l/min. Your heat output is determined ...
@dinhp I will try and upload an audio file as it is difficult to describe how it sounds. The noise level will vary depending on how hard the heat pump...
@dinhp Thanks for the extra info. Your COP of 2.49 for today is not great if OAT is 9C, although it was probably colder overnight. Does this include a...
@dinhp I have a 12kW Gen 6 Samsung and your weather compensation settings look fine. Mine are -5/50 and 10/30, so at 7C OAT our flow temperatures shou...
I am glad to hear that your consumption problem has resolved. On starting, it seems that the compressor ramps up to close to 100% and then modulates d...
There are 2 main display options on your wired remote controller. In both displays the current flow temperature and room temperature are shown on the ...
- 21 Forums
- 1,959 Topics
- 42.5 K Posts
- 16 Online
- 2,272 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
SolarPV tables / online calculator
Is there some table or an online calculator that I can ...
By MichelleC , 3 hours ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
Same here @jamespa - we have a 12kW Samsung ASHP, solar...
By Old_Scientist , 6 hours ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
Yes, that sounds correct. I would say try both options...
By Old_Scientist , 6 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 7 hours ago
-
RE: Setback savings - fact or fiction?
The great thing about science is that it doesn't care o...
By JamesPa , 8 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 10 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 12 hours ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 14 hours ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 15 hours ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 16 hours ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 19 hours ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 20 hours ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 1 day ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 1 day ago
-
RE: Towel rails. An unexpected final hurdle
@jamespa Beware; the use of the term ‘WC’ might lead to...
By Toodles , 1 day ago
-
RE: Visit a Heat Pump sessions.
Congratulations @toodles, that's a fantastic result. We...
By Old_Scientist , 2 days ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@cathyem1 - thanks for the update. Let us know how it g...
By cathodeRay , 2 days ago
-
RE: Low COP and unevenly heated rooms with 12kW Samsung AE120MXTPEH / AE260TNWTEH
@editor But do you wear your peaked cap the right way r...
By Toodles , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
I’d be interested to hear the feedback and consensus on...
By Mars , 2 days ago
Latest Topics
-
SolarPV tables / online calculator
By MichelleC 3 hours ago
-
Samsung Gen 7 R290 12kW is not behaving how I expected
By Joshua 15 hours ago
-
Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
By BAMi 18 hours ago
-
By Toodles 2 days ago
-
Solid manhole cover within r290 exclusion zone
By dbrb2 2 days ago
-
Towel rails. An unexpected final hurdle
By Davesoa 2 days ago
-
By big_si 2 days ago