Quite pleased if that turns out to be 50%. And before anyone is thinking 'soap dodgers', we have electric showers and a dishwasher!
I have MMSP metering so am not using the internal Ecodan power meter. My 14kW Ecodan always uses 24W when in standby; that's no freeze stat, no water...
@Wintergreen, apologies if others have covered... is your total heat loss really 43kW? That's huge; the biggest domestic ASHP I've seen is 16kW. ...
@Beagles, the main thing that catches my eye is your LWT. 40 deg is high for ufh; a well designed ufh system with average room temps should run a l...
Although I now have independent electricity and power meters on my Ecodan, I didn't always. I haven't done any direct, controlled comparisons but as f...
Sounds impressive. How big are they? I would have thought you'd need quite a lot of thermconite to store enough heat. Also, Mrs M wants to know ...
@Transparent, I don't think it's as simple as that. An ASHP running in a reasonably well insulated house can be switched off for short periods (2-3...
It was the cached version I saw then, complete with personal details.
The problem is, it's normally the site owner who is on the hook and the person who will end up being sued. The free press has expensive lawyers to ad...
@newhouse87, I'm not going to try and add to any of the technical advice you've had but ... Up to 70kWh to heat a 240 m2 house to 22 deg at below ...
@heat-pump-newbie, your ASHP is probably running at very low output in the conditions above; 33 deg LWT is barely lukewarm and outside temps are qui...
The Vaillant range is relatively new and should be at the higher end of COPs out there. However, 5.2 for February might be a tad optimistic given the ...
- 21 Forums
- 1,973 Topics
- 43 K Posts
- 39 Online
- 2,304 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
Thanks David. This is another option for sure. Heads a ...
By Sandman1600 , 46 seconds ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@terry1812 sorry didn’t mean to offend. That’s lucky th...
By Adrian , 2 minutes ago
-
RE: Is it KISS or constant – weather compensation vs. set flow temperature?
Away at present. Hence the delay. Will get back asap. ...
By cliffhanger , 1 hour ago
-
RE: DHW temp Samsung AE120RXYDEG 12kw ASHP with Gen 6 controller
@bontwoody The tank is a Kodiak Joule Smart Pre Plumb. ...
By BAMi , 2 hours ago
-
RE: Setback savings - fact or fiction?
The lower the DT the higher the flow rate. The lower ...
By BobTSkutter , 16 hours ago
-
RE: Who's your electricity provider and what's your tariff?
I have now written to OE for clarification on the algor...
By Toodles , 17 hours ago
-
RE: New kitchen with no walls – will fan coil units work?
Thanks. That explains the strangely-shaped 'feet' (loo...
By IanMK13 , 19 hours ago
-
RE: Heat Pump Sizing & Installation Costs
2019 180sqm timber frame 14kW 300l DHW 16 new r...
By Abernyte , 1 day ago
-
RE: Heat Pump Books For Beginners – Bodge Buster & From Zero To Heat Pump Hero
I’ve updated Bodge Buster for 2025 to empower homeowner...
By Mars , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
Aira, the Swedish, end to end manufacturer, system desi...
By KevinPotts , 1 day ago
-
Unfortunately for your argument the best performing Dai...
By RobS , 2 days ago
-
RE: Grant ASHP not reaching target temperatures
@mikefl Thank you. I’m not sure how to do these checks ...
By Hillswick , 2 days ago
-
RE: Transforming a Derbyshire Property into an Energy-Efficient Haven
@carpenterstation That's helpful, thank you. The de...
By Morgan , 2 days ago
-
RE: What is the best strategy for operating a very oversized heat pump?
@jamespa Homely does address many of these issues, but ...
By Arundalep , 2 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
There is absolutely nothing wrong with buffer tanks in ...
By JamesPa , 2 days ago
-
RE: Replacing knackered oil boiler with ASHP - Perthshire
@abernyte thanks tbh I was more thinking about bolsteri...
By DowallyDrifter , 2 days ago
-
RE: Battery storage to run Heat Pump.
@jeff The government are quite happy for the network ...
By Lucia , 3 days ago
-
RE: Adjusting 6kW Daikin's Weather Compensation Curve
@jamespa I'm grateful for your advice.
By Ubert767 , 3 days ago
-
RE: Say hello and introduce yourself
@carrownisky where are you based? Would you like me con...
By Mars , 3 days ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@transparent Good morning, the installer sorted our m...
By Cathyem1 , 3 days ago
Latest Topics
-
DHW temp Samsung AE120RXYDEG 12kw ASHP with Gen 6 controller
By BAMi 14 hours ago
-
Adjusting 6kW Daikin's Weather Compensation Curve
By Ubert767 3 days ago
-
Should I make my radiators smaller?
By Scalextrix 4 days ago
-
Daikin Heat Pump Cycling Frequency?
By Ubert767 5 days ago
-
Battery storage to run Heat Pump.
By Broadsman 5 days ago