Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: May 17, 2026
Topics: 23 / Replies: 4842
Reply
RE: High Temp Heat Pumps for fast warm-up of house

I don't know exactly how long it takes to heat up (and to specify I would need to specify conditions) but in very general terms its 24 hours+ for the ...

3 months ago
Reply
RE: High Temp Heat Pumps for fast warm-up of house

I dont, because I dont turn it off unless Im going away for several days, and in that case the technology to schedule a timed restart (and if necessar...

3 months ago
Reply
RE: High Temp Heat Pumps for fast warm-up of house

Before I got a heat pump I turned down my gas boiler flow temperature from 70 to 50 which was the lowest it would go. The result was a much more comf...

3 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

OK. What Im seeing looks fairly normal TBH: 1 start per hour is good (1028 on off cycles in 1303 hours); there is no evidence of short cycling Un...

3 months ago
Reply
RE: Daikin 6kw setup with Dixell controller

In general pure LWT mode will be more efficient because it means you are operating at the lowest flow temperature. It may well, depending on house, a...

3 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

Wow, that sounds like fun. There is another thread where someone with a Hitachi heat pump (featuring a more conventional vertical fan) describes a si...

3 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

@davidb Further to my previous post one further comment I would make is that 300l system volume is not consistent with 7 radiators. Unless you have a...

3 months ago
Reply
RE: MCS - BS EN 12831-1:2017 – Heat Loss Survey

Since May 2025 it no longer a requirement in England to benefit from permitted development rights (ie planning consent without having to make a planni...

3 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

@davidb Once again I agree with Adrian. Houses have memory and different bits cool at different rates. So for example (this is just one mechanism...

3 months ago
Reply
RE: Need help maximising COP of 3.5kW Valiant Aerotherm heat pump

I agree with the comments made by @adrian both about the fire and the DHW. You should also bear in mind that, with a low loss house, COP isnt so impo...

3 months ago
Reply
RE: MCS - BS EN 12831-1:2017 – Heat Loss Survey

I think its small, but off course it could happen so please dont rely on it. They do a sample check of some kind on installers and my system was chec...

3 months ago
Reply
RE: Hoped for improvements not being realised on my Mitsubishi heat pump

I have been wondering that myself. The fact is that, even with the buffer (meaning that the secondary pump doesn't have to push water through the pi...

3 months ago