Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 11, 2026
Topics: 27 / Replies: 5486
Reply
RE: Mixergy Tank Failure

I think the mixergy coil is quite small, they sell an add on circulator and phe for heat pumps. I don't know how Samsung's algorithm works but is it ...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

If its set to active then the HP will adapt the WC curve (to an undisclosed extent and with an undisclosed timescale) to achieve the set temperature, ...

12 months ago
Reply
RE: Options on flushing my system

FWIW my flow crashed when I started my system up in July to attempt cooling for the first time, the space heating part of it having sat around doing n...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

If you screw them right down yes, but not if you don't. The ones that came with my TRV4s actually have moulded arrows on them labelled ,+/-  

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

I dont have them I balanced on the LSVs. Its a bit fiddly because they typically only make a difference in the last turn to half a turn (see heat Gee...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

No vibration issue. However when its minus temperatures and compressor modulation >80% there is noticeable compressor noise. The rest of the time...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

My single Mitsubishi ilife2, which is otherwise perfection, suffers from exactly this problem and the threshold (30C) isn't adjustable. I've just (ye...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

The first chart in your post above shows average 0.25kWh consumption. The second confirms that the unit is delivering less than 1kW output. Yet the ...

12 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

You should be getting better than that at this time of year even though it will be cycling, unless it's really cycling a lot (short cycling). Can you...

12 months ago
Page 200 / 460
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Click to access the login or register cheese
Protected By
Shield Security PRO