Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Jun 10, 2026
Topics: 25 / Replies: 4955
Reply
RE: Renewables & Heat Pumps in the News

This is IMHO too simplistic and possibly based on something of a prejudice that the government 'must' be wrong When solar panel grants and the FIT t...

7 months ago
Reply
RE: Renewables & Heat Pumps in the News

Firstly its still speculation so worth only limited time. If I were in government I would definitely want to look at this. There are always options...

7 months ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

If you go on Freecycle or look in local skips near building sites you can usually find offcuts of insulation board. You need permission to take stuff...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Really sorry to hear that. The building trade is just dodgy, the world over it seems. Did you see the video of that vast bridge in China that colla...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Thinking about it BUS is installer tied I believe. As a householder you have to consent to a particular installer claiming the BUS grant. I dont kno...

7 months ago
Reply
Reply
RE: Who's your electricity provider and what's your tariff?

Hmm, Interesting. Their export tariff 'pays out' only at the end of the end of the year and I have always wondered if I will have trouble claiming it...

7 months ago
Reply
RE: Confused by Flow Rates

Cycling will always occur if the demand from the house (essentially the heat loss at the current OAT) is less than the minimum steady state output of ...

7 months ago
Reply
RE: Confused by Flow Rates

Only to the same extent that outside temperature, or room temperature 'controls' dT. Its certainly true to say that dT may vary as a result of changi...

7 months ago
Reply
RE: Confused by Flow Rates

Heat pumps cant do the first directly because its not something they directly control. DT is determined by the loss from the emitters (which is in tu...

7 months ago
Reply
RE: Maximising Home Automation: Integrating Octopus Energy & More

I thought I has answered this; I think the answer is NO because of the bits in italics.    

7 months ago
Forum
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

This problem occurs, to a greater or lesser extent, with any heating system really whether ASHP. Oil or Gas and isnt special to Grant in the ASHP worl...

7 months ago