Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 4, 2026
Topics: 27 / Replies: 5447
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

Surely the drops to the radiators are in parallel not in series, so the index circuit for pressure drop calculations will be determined by the longest...

4 weeks ago
Reply
RE: Where heat loss surveys seem to go against practical reality

I have one Mitsubishi Ilife2-slim fancoil to solve a problem that otherwise would have required either a large K3 or a superlarge K2. Its really quit...

4 weeks ago
Reply
RE: Surface mount or bury primaries for heat pump installation?

@tomasmcguinness Has it changed colour between photos or is that just the evening light?

1 month ago
Reply
RE: Where heat loss surveys seem to go against practical reality

@ian33a Given the nature of your house I think you did well to get estimates that close. I have to agree with this sentiment: and also The...

1 month ago
Reply
RE: vaillant aurotherm - Using Heating

Mine does the same, but recordw is only about 6kWh/month. I assume its a combination of quiescent power consumption, some of the things it does reg...

1 month ago
Reply
RE: Missing flow temperature in Heat Geek proposal

I can imagine 'get outs' but doubt they will use them. Heat Geek do appear to be 'industry leading' in offering this guarantee, and everything we hea...

1 month ago
Reply
RE: Missing flow temperature in Heat Geek proposal

Quite probably, does the guarantee come with any definitions of terms   Quite possibly yes, albeit perhaps surprisingly. Here is a plot f...

1 month ago
Reply
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S

Good but - with your recirculating pump a high proportion of our DHW consumption is actually heating the house! Best to bear that in mind!

1 month ago
Reply
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S

@cathoderay if I could give two thumbs up for that post I would. However pressing the thumbs up a second time deletes the first. I concede that this...

1 month ago
Reply
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S

I would agree with this if it were not for the material discrepancy with this graph (the flattening off of which at low temperatures can be explained ...

1 month ago
Reply
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S

Ah. If the 'secondary pump' means a water circulation pump, that explains the very high apparent DHW usage. If so its not actual water usage, its en...

1 month ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

I don't for certain. There are a couple of possible installer parameters namely conf heat build pump, unit %pwm, default auto, but can be set 50%-1...

1 month ago