Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Apr 29, 2025
@jamespa & @derek-m Readings . Here are the readings from the Thermocouples as requested. 1) Sen1, Thermocouple . Note the Saturatio...
@jamespa Success again!************!! Your idea of increasing the Water Law defining coordinates [+15:25] to [+20:25] has revealed a great deal a...
@jamespa Water Law change: I have changed the Water Law determining coefficients to [+20:25] as requested. Graphs with sensor Position ...
@derek-m My Sharky: My sharky model no is: de-10-m1004-ptb003 Manufactured and built in Germany with the CE Test stamp and Calibration Par...
@jamespa Could I ask a question with my Electrical "Cutty Sark" showing? Radiator Water Power , with an Run Time of 3 minutes and a Cycl...
@jamespa Measurements using Sharky Water Meter. My Sharky , as , I suspect most Water meters ,is: 1) Designed for a Landlord to find the Water ...
@jamespa Hi James, Unfortunately the Heat Pump has taken over my entire life! Gathering all this data , fixing all these problems , spending ye...
@derek-m & @jamespa Improvement amongst the noise! Here are more statistics from my heat Pump: The COP and REAL COP have returned t...
@derek-m & @jamespa Secondary pump continuously ON Primary pump continuously ON The Fact that BOTH pumps are continuously ON Should redu...
@jamespa Measurement problems. The Measurements from My Sharky have now settled down following an hour long incident where the Sharky reading...
@derek-m Nail on Head! You have , again , hit the nail on the head with your question about decimal points et al. The Sharky produces , interna...
@derek-m Hi Derek, Here is the Sensor 1 recording of Heat Pump output sensors last night taken with a Thermocouple Clamped to the pipe , i.e. not...
- 27 Forums
- 2,767 Topics
- 65.1 K Posts
- 1,642 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you are considering phasing the project, then I woul...
By GrahamF , 3 hours ago
-
RE: Siting of the external sensor on a heatpump
Of course had the heat source been a heat pump it would...
By JamesPa , 5 hours ago
-
Never assume, it makes an ass of u and me! OK, tha...
By JamesPa , 5 hours ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 7 hours ago
-
RE: Is it the house or the equipment?
@springswood We have two Daikin single split A2A syst...
By Rob of York , 8 hours ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 1 day ago
-
No, but the heat pump must be capable of delivering a S...
By JamesPa , 2 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 2 days ago
-
RE: Vaillant Arotherm Plus 7KW need a service on it
booked it with Vaillant. will use them until i can find...
By AdamK , 2 days ago
-
RE: Adventures in heat loss calculations
I have seen it stated that the declared calorific value...
By JamesPa , 3 days ago
-
RE: Two heating zones to one zone
@transparent Many thanks. The garage is fairly well ...
By Profzarkov , 3 days ago
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 4 days ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 4 days ago