Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

iantelescope
@iantelescope
Contributor
Reputable Member
Joined: Mar 29, 2023
Last seen: Apr 29, 2025
Topics: 1 / Replies: 417
Reply
RE: My horrific Samsung heat pump installation and experience

@iancalderbank hi ian DS18B20 I have , at the moment , several DS18B20 's attached to the Heat Pump. These are excellent , but, no re...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m What do you think of this plumbing software. Allegedly calculates Pressure drops , Temperatures , losses from a AutoCAD style fro...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Yes Derek, I agree with you .......... I should have Designed my Heat Pump myself. External pipe Temperature Sensors? The Only af...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@fazel fazel, I am green with envy. If only I could get Six cycles per day ! I have a system that was NOT designed , but , chosen becau...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Many Thanks Derek. My Water Law settings are : The Water Law Graph is defined by several bits in the Samsung Controller memory. ...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Thanks, Derek An Excellent display of Simple clear Technical writing . Can you define "Short Cycling"? Is this short Cycling , a...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa Excellent clear Technical writing James! I accept, reluctantly , that a whole system model is impractical. My immediate problem is...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Cycle Period ? What is your current "Cycle Period "? Currently my own cycle period is 10.5 minutes with up to 110 cycles per day i...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa Thanks James, I was not aware that the result of the Water friction was to reduce the pressure drop , not the Temperature. At le...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Yes, I now appreciate that I was misinformed by the Frenchman. However, my "intuition" still insists that the pipe Friction loss wil...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa Temperature Drop and flow rate Again, James you are probably correct. However, my "intuition" is still basically that of an Electr...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa Am I Sure of Temperatures ? No, I am sure of nothing! The Water Temperatures are measured , in the main , by Chinese K Type senso...