RE: My horrific Samsung heat pump installation and experience

@derek-m BS7593: Addendum 2019 Because of this : I get this, in my Pipe water Supply * My Heat Pump, this year , every year...

7 days ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek & @derek-m & @Mars PWM STATUS RETURNS: This is the Status Returned from the Primary Grundfos motor when driven by an Ardui...

1 week ago
Reply
RE: My horrific Samsung heat pump installation and experience

@derek-m Inrush currents and Relays on Samsung -Grundfos Heat Pumps. The Grundfos Motors , unusually for motors , present a Capacitive Load to th...

1 week ago
Reply
RE: My horrific Samsung heat pump installation and experience

Topic starter 18/07/2024 10:29 am @technogeek & @derek-m @Mars PWM OR RELAY ? BS7593:2019 Should the Water Pumps on ...

1 week ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek & derek-m @Mars PWM OR RELAY ? BS7593:2019 Should the Water Pumps on my SAMSUNG HEAT PUMP be Regulated , and SWITCHED ON an...

1 week ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek & @derek-m IS the PWM Control on my GRUNDFOS MOTOR FAILING ? Sorry, @Technogeek , I intended No offence. Please accept my apolo...

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek Floating SAMSUNG Power supply ? Should I connect the o V on my SAMSUNG Heat Pump to Earth? My O volts has , currently , a 14....

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek SAMSUNG EARTH / NEUTRAL/ Problem My PWM Reference pin has a 14.7 VAC voltage with respect to both earth and local Mains Neutral....

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek & @derek-m @Mars !!STOP COP !! MY AVERAGE REAL COP IS 2.0 . With the second anniversary of my SAMSUNG HEAT PUMP FIASCO ...

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek Sorry for the senior moment , I meant floating neutral! I have never heard of floating neutral but have certainly experienced Eart...

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek Floating Earth?? I would Not be surprised if the Mains wiring , like everything else, was wrongly installed. Hi @technogeek...

2 weeks ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek & @derek-m My PWM Signal is being killed by my Grundfos!. Hi Again, thanks for your patience! What are your Samsung Inv...