I have never checked but I assumed all my secondary pumps are running during a defrost as there is only 10M of 28mm pipe in the primary not sure what ...
@morgan just go to the login to the website hcas has provided, that just gets the data across to them they won't take control until you request it.
@clockworks I have never tried to use a wireless controller before so will be interested to find out how it goes. I would hope the dip switch change...
@harriup I believe these offsets only work in autoadapt mode and not in weather compensation mode which is why I were suggesting @clockworks gets his ...
@wvtienen1 Yes its controlled by a signal to the pump, if I change the value on the heatpump controller I can hear the pump speed up or slow down and ...
@wvtienen1 There is a flow meter that measures the flow rate and can be accessed on the heatpump controller, the pump speed/power can be set from th...
@clockworks The only way to detect defrosts from the data is as you say to see the flow temp drop below the return. You should be getting defrosts wh...
The short answer as always is it depends, different models do it differently. Mitsubishi is constant flow rate so as the heat pump modulates down you...
@clockworks or get your installer back to fix it, the cycling you are getting isn't acceptable, the MCS guideline talks about volumisers to ensure the...
@morgan Havenwise uses the data that is fed to Melcloud so it could work for you. I haven't inquired but I would expect you to need to be using the m...
The hot water mode is the settings on FTC6, I think you are thinking of separate pump speeds for heating and DHW which is only on FTC 7, its in the vi...
@jingle86 Thats in the Ecodan ATW Databook Volume 6.0 /p> No idea what they mean that's why I suggested calling the technical help line they are...
- 26 Forums
 - 2,265 Topics
 - 50.6 K Posts
 - 601 Online
 - 5,924 Members
 
Join Us!
Podcast Picks
Latest Posts
- 
                        
RE: Help me keep the faith with my air source heat pump installation
@jamespa I contacted the installer and asked them to ba...
By AdamK , 37 minutes ago
 - 
                        
RE: UFH downstairs and radiators upstairs balancing question
@walnut-tree-cottage My bad, sorry I transpose while tr...
By ASHP-BOBBA , 2 hours ago
 - 
                        
RE: Who has a V2G EV installation
They certainly look stylish! But it seems that Ander...
By Batpred , 2 hours ago
 - 
                        
                                RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
And if MCS don’t have one on record that’s an issue bec...
By Mars , 3 hours ago
 - 
                        
                                RE: My DIY Heat Pump installation
@polar-bear, I take my hat off to you. I wish I had the...
By Mars , 3 hours ago
 - 
                        
                                RE: Electricity price predictions
One persons view In sync with the Nesta figures s...
By Jeff , 5 hours ago
 - 
                        
                                RE: Oil Boiler & Heat Pump Hybrid System
So in that case they do have an incentive for you, as t...
By Transparent , 6 hours ago
 - 
                        
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
Ok so that seems to be the key point namely only mcs ca...
By JamesPa , 7 hours ago
 - 
                        
RE: One flow valve appears to be duff
You might want to consider the following common faults:...
By IaAck , 14 hours ago
 - 
                        
                                RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
We are on the Intelligent Octopus Go tariff. We instal...
By GrahamF , 17 hours ago
 - 
                        
RE: New build installation query
@paullacey While the others wait for more info do you m...
By ASHP-BOBBA , 1 day ago
 - 
                        
                                RE: British Gas Heat Pump Installation Complaint
@bgno, the other consideration for legionella cycles ar...
By Mars , 1 day ago
 - 
                        
                                @old_scientist I dont monitor the tank temperature but ...
By bontwoody , 2 days ago
 - 
                        
                                RE: Say hello and introduce yourself
Hello @paultheheating - I'm a rural Moderator! What's...
By Transparent , 2 days ago
 - 
                        
RE: What valves to replace radbots?
Yes. Radbots just replace TRV heads. TRV heads push t...
By JamesPa , 2 days ago
 - 
                        
RE: When will fusion be producing energy?
I am thinking of the case where AI was able to distingu...
By Batpred , 2 days ago
 - 
                        
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Very definitely. I think the market has changed a bit...
By JamesPa , 3 days ago
 - 
                        
                                RE: Buying large amp bidirectional RCD and RCBO
The following diagram is taken from the Meter Operator'...
By Transparent , 3 days ago
 