I think that you will find that the 'soft' start for an electric induction motor is only over a period of seconds, to limit the current inrush. The ...
Just a note of caution. Correctly optimising the WC curve can literally take weeks to achieve dependent upon variations in weather conditions. Only ...
It is interesting to see how the compressor appears to go up to maximum speed when the actually LWT is quite low when compared to the target value, wh...
If I am understanding correctly, your WC curve is set to LWT of 35C @ OAT of -4C and LWT of 30C @ OAT of 20C. So at an OAT of 0C, the LWT should be in...
@cathoderay So on your particular system, when in setback mode, the whole system appears to be disabled, including the water pump or pumps. When cyc...
It may have been adequate a few days ago, when the OAT was higher, but now 35.5C could be inadequate. Your system cannot be operating in WC mode if ...
@cathoderay The data that you are providing is extremely useful, because it not only provides a better insight into how heat pump controllers appear...
If you run your heat pump on a fixed LWT, the IAT will likely vary with changes in OAT. Applying a 1C setback may have just made matters worse. If y...
That would be the case if the water pump keeps running for the whole compressor off period. I believe that some heat pump controllers can be set to ru...
I would suggest that you check the location of the temperature sensor on your hot water cylinder, since if it is fitted too high up the cylinder you m...
@jamespa Hi James, I would welcome your thoughts on the following. Calculating the thermal energy output from heat emitters is fairly straightfo...
@guthrie I know that some controllers can be removed from their main housing and relocated using a suitable extension cable, but I'm not certain if ...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 589 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
How long will your energy contract last?
Some heat pump tariffs don’t run as long as a heat pu...
By Toodles , 6 hours ago
-
@morgan They are unsupervised these days, can’t get the...
By Toodles , 6 hours ago
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@kevh it's worth remembering that many lsvs only actual...
By JamesPa , 1 day ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 1 day ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 2 days ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 2 days ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 2 days ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 2 days ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 2 days ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 2 days ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 2 days ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 2 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 2 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 2 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 3 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 3 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 3 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 4 days ago