I would, but at the moment I have what I think is the right balance between getting a saving and comfort. I have a bit of a cliff edge as the IAT fall...
The latest last 24 hours of data: Pretty much as before, steady and mild OAT at around 10 degrees, heat pump cycling around twice an hour to m...
I have never said all heat pumps are Mideas, quite the opposite, nor have I ever said all systems have primary and secondary pumps, again, quite the o...
@bob77 - I think your understanding is correct, at least for some systems - other heat pumps may/will vary, but on a Midea setup, the secondary pump i...
@derek-m - I think we need to consider whether there is a heat exchanger or not, and if so, which pump we are talking about. In my case there is, and ...
@bob77 - with the caveat that I have a heat exchanger, and so a primary and secondary pump - it does look like the secondary pump runs continuously wh...
Here we go, data from the last few hours since I added compressor frequency to the data, as it happens a period of relative stability in OAT, though i...
I'm already doing that, and most of the time it works, but I still have to iron out a bug, running my hourly auto-adaption script, which varies the LW...
@mikefl - a useful comparison, even if it is, I agree, a rather busy chart! There is a more marked spike, but there is also a notable dip after the sp...
That's by intention, achieved by using the room stat timer as an on/off switch, by setting it to 12 degrees for off, 26 degrees for on. I could do the...
I'm sorry, but I don't have a lot of time for those emoncms how not to do a chart charts. There is no legend, meaning there is no way of knowing what ...
@derek-m - my heat pump appears to keep the flow rate steady, unless the heat pump is completely off. Flowrate (m^hr) added in gold, trace for last 24...
- 26 Forums
- 2,289 Topics
- 51.4 K Posts
- 288 Online
- 5,949 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
we are talking the same thing. Its crazy if its really...
By JamesPa , 28 minutes ago
-
RE: Electricity price predictions
I agree, the operation of a system managing hundreds of...
By Batpred , 28 minutes ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@jamespa Yes, the OAT sensor is situated on the back pa...
By Toodles , 29 minutes ago
-
RE: DHW heat loss through pumps.
Ah, you have a water circulation loop, (like in hotels)...
By JamesPa , 34 minutes ago
-
RE: Ecodan ASHP Low COP and Unstable Compressor Frequency
Just to clarify, returning water from UFH is colder tha...
By lukewarmbath , 43 minutes ago
-
RE: 10kw heat pump run in 24*7 data?
A different heat pump (Midea 14kW) but a stark reminder...
By cathodeRay , 52 minutes ago
-
From what I see, the work to upgrade the cable, etc all...
By Batpred , 1 hour ago
-
RE: Confusion over Octopus Tariffs
That's sounds great. I have no ASHP, but 15kwh storage....
By Batpred , 2 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Locked environments are difficult to manage, it also me...
By Batpred , 2 hours ago
-
RE: Do Heat Pumps need to start up at Full Power?
@steelbadger Attached is the plot for various parameter...
By Toodles , 6 hours ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Hi all, I had a 15kw installed 3 weeks ago. The past we...
By jamesh , 7 hours ago
-
Adia Therma - 'autopilot for heat pumps'
Thought I'd pop this one in here as the Adia proposal a...
By seatonian , 21 hours ago
-
RE: Mitsubishi Ecodan R290 10kW performance
Don't know answer to final question. Your contract p...
By JamesPa , 21 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Ah, it seems PACE BMS are easy to source on AliExpress,...
By Batpred , 22 hours ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
@jamespa Agreed I don't feel concerned about this, espe...
By jeegnesh , 23 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@toodles Yep, and it is not even a sticking plaster ...
By Jeff , 1 day ago
-
RE: Renewables & Heat Pumps in the News
I agree, imperfect systems like voting for politicians ...
By Batpred , 1 day ago
-
RE: Gov wants to alter our FIT contracts from rpi to cpi
The consultation is just part of the normal process for...
By Jeff , 1 day ago
-
@transparent @old_scientist Quick update, I submitted...
By Batpred , 2 days ago