@toodles Good point lucky you. Yes mate I also have some compression on them will address this also fun times for me ahead 😅
@lokisam I did have a MCS Audit when the installers finished I got randomly selected for this on their system. But it was very basic and they do...
Here is the pipe running into the wall a little more exposed showing that it's not insulated through the wall
@lokisam Love a good rant sounds like yours is moving in the correct direction buddy glad to hear it 👍 thank you
@transparent Yep just had a reply from NAPIT to leave everything alone for when they request more picture evidence. So that solves that 😅
Found some more that hasn't been sealed from the elements 😕
@transparent Good shout I do have some insulation I could use as a temporary cover without disturbing the work they have done. Fingers crossed I...
@transparent Currently just spoken to installer, and then MCS who have passed the case onto NAPIT as the installer has said they will take no furth...
@transparent You are correct it's a close up of those two and in the correct orientation as pictured. That pipe on the right is not insulated th...
And you can just about see from this picture that it's not insulated through the wall note the cement around the pipe. I believe this is transferring ...
Completely missed this when I was looking over the external insulation the other day. Not sealed from the elements so probably soaked up a load of ...
My Midea r32 6kw(5.7kw rounded up) supposedly runs as low as 25⁰c and regularly seems to pull just 500/600w but that includes the base load of the hou...
- 26 Forums
- 2,199 Topics
- 48.4 K Posts
- 46 Online
- 5,854 Members
Join Us!
Podcast Picks
Latest Posts
-
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@pirate-rich there’s a lot to do and plan, and the wish...
By Mars , 7 hours ago
-
RE: Why Air Release Valves and Deaerators are Non-Negotiable
@chas-b and @pirate-rich spent the day with us today ta...
By Mars , 7 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk Its a bit complex: My 28mm primaries run for a...
By JamesPa , 8 hours ago
-
Can you separate out the scop data between hot water an...
By Andrew J H , 10 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Further, these bar charts may throw a few more lumens o...
By Toodles , 11 hours ago
-
RE: Heat pump and wifi kit connection.
Wi-Fi kit covers any Samsung device that has a modem in...
By Alfapat , 1 day ago
-
RE: How to Understand Wiring Up a Heat Pump
I’m watched @pirate-rich rewire our wiring centre last ...
By Mars , 1 day ago
-
RE: Sizing - Save me from my headache
If you get an R290 pump you should be able to heat the ...
By JamesPa , 1 day ago
-
RE: Large heat pump options for church building
@aventus-eco Thanks Sean, will drop you a line.
By Josephiah , 1 day ago
-
RE: Moving FIT array onto a Tesla Powerwall 3 possible?
@toodles that’s good news for @adamk
By Judith , 1 day ago
-
RE: Samsung Gen 6 - Schedules not working
@technogeek That sounds very logical :-). I will give i...
By bontwoody , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
Considering Octopus states all their electricity is gre...
By AgentGeorge , 1 day ago
-
RE: Heat Pump + Tado Setup: Smarter Control for Secondary Pumps?
@pirate-rich thanks for the reply. If I were to explo...
By Lloydi , 1 day ago
-
RE: Seal the Deal: Don't Let Your Heat Pump Leak Energy
@transparent I think the committee might get into some ...
By Toodles , 2 days ago
-
Samsung ASHP Support in Midlands area?
Hi all, Per title.... can anyone recommend a ASHP ser...
By Andehh , 2 days ago
-
May I present the maths I referred to earlier when disc...
By Transparent , 2 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
How many times and dates have epc sap rules been change...
By Tim441 , 2 days ago