Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 19, 2026
@toodles I'm still in the NAPIT stage so will have to wait and see then back to MCS to see where we can go from there. I wish I paid on credit c...
@editor Seems like it's going that way buddy. Near 3 months as well not including the months prior to this I've been asking the installer to sor...
SMALL UPDATE... This morning I have had Daniel from MCS reply solid bloke trying to help. Basically he emailed NAPIT (29th Nov) saying the inspec...
@cathoderay sorry forgot to add that around 40 mins
@cathoderay full heat cycle in 5 minute intervals from 25⁰ to just before it hit 45⁰ Flow basically stayed at 0.5M³/h Temp difference between pla...
@cathoderay Interesting 🤔 Mines being the 6KW looking at that data you provided there it's running right on the bottom end for flow.As l...
@cathoderay Will try and grab these next time or I may force it to go to 50⁰ just to check. I keep it at 45⁰ and just let it top up we have a 150L ...
Hot water running this time similar flow rates. Phoned Midea and they said yes most likely a plumbing problem
@cathoderay It's all a bit over my head all this maybe one day I will dig into it deeper but really I shouldn't have to. I have spoken to freedo...
@cathoderay That's with it running fan spinning I assume
- 27 Forums
- 2,768 Topics
- 65.2 K Posts
- 1,661 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 2 hours ago
-
RE: Who's your electricity provider and what's your tariff?
Hope you are hearing from a good source? Call me old ...
By Batpred , 2 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
The Heat geek contract had various get-out clauses with...
By Batpred , 4 hours ago
-
RE: Why are ASHP installs so expensive?
It seems a quite comprehensive breakdown. I will try to...
By Batpred , 4 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 10 hours ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 12 hours ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 13 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 22 hours ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 1 day ago
-
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 2 days ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 3 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 4 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 4 days ago