RE: Is my Samsung heat pump working too well?

@heatgeek Isnt the DT steady at 5C? The only time I can percieve it isnt is when starting up and its trying to get to temperature. The flow and return...

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@heatgeek No. I can confirm it does have the facility for PWM control. Just an appropriate pump and a lead is needed

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@heatgeek Hi, its run on pure WC, open loop system with a PWM controlled pump. The controller is in the living room and set to stop the heat pump if t...

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@pooneil Unfortunately the controller is wired with a two wire cable. It is measuring your internal temperature so if its in a cupboard, thats not ide...

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@pooneil That can be moved quite easily into another room if necessary. Mine acts as a limiter in case the room gets too hot because of solar gain and...

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@pooneil This is how to alter the water law settings

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

OK, so the low flow error could well be because you are closing radiators stats down, I think. Its certainly not the way to control your heat pump. ...

1 month ago
Reply
RE: Is my Samsung heat pump working too well?

@pooneil Hi. It’s a nice problem to have 😁. Do you know if the system is running using weather compensation? It’s called water law by Samsung

1 month ago
Reply
RE: Help me keep the faith with my air source heat pump installation

@adamk I think I would insulate as much as I could then.

1 month ago
Reply
RE: Help me keep the faith with my air source heat pump installation

@old_scientist good point about increasing the size of the emitter!

1 month ago
Reply
RE: Help me keep the faith with my air source heat pump installation

I would as I would like the heat to be emitted in the room primarily but there is a school of thought that thinks as long as the heat is going into th...

1 month ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

Oi! That’s a yellow card now 😂😂 Seriously though the 5kW gen 6 doesn’t have a noise issue. It seems to be the bigger ones that do.

1 month ago
Page 3 / 68
Share:

Join Us!

Trusted Installers

Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.

✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available

👉 Find your installer now!

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security