I think the low dT is a consequence of the low flow temp you are trying to use, 1.5-2 is small but although a dT of 5 is often cited as optimum, i don...
@johnnyb Thanks :-). I’m off out on a Xmas do tonight but will sit down and try to answer as many of your questions as I can tomorrow.
@johnnyb This formula does seem a bit contenious, but the results do seem to me to be closer to what is expected (obviously not to everyone though see...
@dunlorn @mike-h So the original post comes from the Heat Pumps UK facebook site, reference to it are shown below. The seem to think that the si...
@johnnyb So I think what might be happening is at the very low flow temperature you are trying to use, you cannot get the UFH to release enough energy...
@dunlorn @mike-h I’ll try and get the original post where this was stated as an excerpt was passed to me. unfortunately I don’t find that the Sa...
Hi @johnnyb I have the same heat pump as you but use radiators not UFH. You should be able to run the UFH on a lower flow temperature than radiator...
@dinhp Ive just come across some info that improves your SCOP. I was dividing your Generation kWh / Usage kWh to get COP, but it appears Samsung hav...
@pressure Well mine was a new installation in this house, but if upgrading I would definitely install anti frost valves if you are using antifreeze so...
Couldnt you just replace the old Heat Pump unit, leaving everything else as it is? My 5kW Samsung cost just over 2K last year and its simple to switch...
I remember watching a heat geek video about the effects of unheated rooms and how it would impinge on efficiency as the flow temperature in other room...
@jancold yes it’s fine to oversize them, you can just limit their output as required with the valves. It gives you some more flexibility as to room...
- 22 Forums
- 2,084 Topics
- 46 K Posts
- 26 Online
- 3,377 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
@cathoderay thanks I have just figured it out. You need...
By benson , 2 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
@ashp-bobba thank you, and equally so, thank you for ta...
By Mars , 7 hours ago
-
@judith good to know… I’ll continue to feed Wattson, an...
By Mars , 18 hours ago
-
RE: Vaillant AroTherm Plus 7kW
@jamespa I have a hydronic baseboard heater in the kitc...
By Scalextrix , 24 hours ago
-
RE: My misgivings about installing ASHP and solar panels via the ECO4 scheme...
@editor great article re accreditation. I note ISO/IEC ...
By Bart , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Here’s a little more technical detail/p>
By Judith , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
I don't (yet), but my PW3 is due to be installed shortl...
By Old_Scientist , 2 days ago
-
RE: MCS and NAPIT complaints process
@chrislay, is your heat pump complaint still unresolved...
By Mars , 2 days ago
-
RE: ASHP Install from hell - help please
@saf1973 I’ve been going through old cases on the forum...
By Mars , 2 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@aaron There's the rub, the database does not list my ...
By AF1 , 3 days ago
-
RE: Commencing on an ASHP Installation Process
Yes, it's "doable" if everything goes to plan, they arr...
By Old_Scientist , 4 days ago
-
RE: How not to install a heat pump
You are right. Thinking on this has evolved over the p...
By JamesPa , 5 days ago
-
RE: DHW SET UP with Samsung gen 5
Thats good news indeed, you are very likely almost ther...
By JamesPa , 5 days ago
-
RE: Plate heat exchanger considerations
As far as I can tell my vented system would have a peak...
By Scalextrix , 5 days ago
-
RE: Air Changes per Hour - ACH and the MCS requirement
There have been a few discussions dotted around (e.g. I...
By Declan90 , 5 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
Having made some enquiries locally I have found a compa...
By Morgan , 5 days ago