Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

AllyFish
@allyfish
Contributor
Prominent Member
Joined: Oct 31, 2022
Last seen: Mar 16, 2026
Topics: 23 / Replies: 494
Reply
RE: Need help explaining how my ASHP heats home vs. water

Hi Emma, check what your house thermostat is doing set at 16/17degC. Is it switching the ASHP on and off continuously? If it is that's a very ineffici...

3 years ago
Reply
RE: Rate the quality of your heat pump design and installation

@knukes Hi, thanks for sharing. The Grant weather compensation parameters are quite straight forward to adjust once you get into the settings in the l...

3 years ago
Reply
RE: Not having a good time with my Daikin ASHPs (yes, plural)

Hi Chris, there's some fantastically experienced and knowledgeable ASHP people here, you've come to a good place for help. As others have said, based ...

3 years ago
Reply
Grant Aerona ASHP install and Growatt Solar PV install (both by Thrift Energy)

I don't think you're that far wide of the mark Mars in your estimate. 7/10 'could do better' would be my honest appraisal. ASHP: tidily installed wo...

3 years ago
Reply
RE: Observation about radiators and weather compensation

@derek-m Hi Derek, the primary pump is the one in the ASHP, which for the Grant Aerona range is a fixed pump curve device. It's for exactly this reaso...

3 years ago
Reply
'Things' = digital mini thermostats!

@derek-m, correct, the digital thermometers from Amazon Kev gave a link to. Nifty little things. Cost £11 or so on Amazon Prime for 4. The low loss he...

3 years ago
Reply
RE: Observation about radiators and weather compensation

@kev-m Hi Kev, great minds. I've just fitted 4 of these to my newly installed system either side of the low loss header/volumiser, to read the primary...

3 years ago
Reply
RE: Sceptic to Grant Aerona 3 10kW ASHP convert

@hughf The HIVE was by the installer, not Grant. It works for me as I can zone various rooms in the house on smart TRVs to boost temperatures to suit ...

3 years ago
Reply
RE: Sceptic to Grant Aerona 3 10kW ASHP convert

@derek-m Yes. 50degC to 30degC heating water supply temperature depending on outdoor temperature. Weather compensation active from 20degC to -4degC. ...

3 years ago
Reply
RE: Sceptic to Grant Aerona 3 10kW ASHP convert

Hi @Mars, yes, a brand new install. First winter off kerosene. I either needed to replace a 25yr old oil boiler, with a newer condensing oil burner, o...

3 years ago