RE: GivEnergy 2025 forthcoming batteries and inverters

How much research have you done into this? The large V2G trial undertaken by OVO/Kaluza 5 years ago could only be offered to drivers with a Nissan L...

11 months ago
Reply
RE: Double heat pump for DHW?

That's a tricky issue, and one which I expect to see being raised many times this year (2025) as consumers begin to realise what GivEnergy's strategy ...

11 months ago
Reply
RE: Double heat pump for DHW?

It certainly would @ianmk13There would appear to be an excess of phases to the tune of +1 🤗 Contrary to what we in UK might imagine, 3-...

11 months ago
Reply
RE: Double heat pump for DHW?

Yes. DNOs are very keen to upgrade domestic properties to 3-phase. The swapping of the Smart Meter to a 3-phase device is also free, and gets done b...

11 months ago
Reply
RE: Heat pump quotes: Advice needed

As this topic is being read by an OP who is still evaluating quotes for an ASHP,I'd like to add a comment about Vaillant. I've noticed that they hav...

11 months ago
Reply
RE: Double heat pump for DHW?

Thanks Bob. Could you just clarify what you mean by setting "the ASHP power at 12kW"? Yes, I appreciate that 12kW may well be the largest you'd su...

11 months ago
Reply
RE: Heat pump quotes: Advice needed

One other point about microbore, or any system where the pipework isn't adequately sized for the required transfer of heat... To obtain the desired ...

11 months ago
Reply
RE: Heat pump quotes: Advice needed

It might be 'standard' in that it complies with the way MCS-approved installers are required to undertake calculations... 😥 ... but the lower ...

11 months ago
Reply
RE: Ecodan Legionella cycle - immersion heater problem

OK @clockworks - I agree with your analysis. So what you're seeing here is due to the relatively slow rate at which heat is rising in the tank. ...

11 months ago
Reply
RE: Ecodan Legionella cycle - immersion heater problem

I've just superimposed those and adjusted the x-axis to make the time-frames coincide... I think Mitsubishi need to justify the need to send the i...

11 months ago
Reply
RE: Double heat pump for DHW?

Thanks Bob. For such an elderly plate heat exchanger, yours is in a cupboard which is remarkably free of cobwebs! So that others can see what we'r...

11 months ago
Reply
RE: Double heat pump for DHW?

Can we have a photo of that plate heat exchanger please @bobtskutter ? Plus your comments on why this is preferable to having a coil inside the cyli...

11 months ago