Last seen: Sep 14, 2025
Like any other domestic 'frost-stat', the BUH temperature system is there to protect your pipes from freezing. It has no concept of whether 'heat is...
I don't expect they'll use more than 1 temp sensor on the outside unit. Look at your graph.There are three areas of interest The red sector is c...
Well I'm guessing that the temp sensor is positioned where it has access to the surrounding air, but isn't within the air-stream which gets drawn thro...
This joke's on me. It's often the case that I use a 3D printer to create a few components needed for an 'energy project'. These can sometimes take...
The actual outside temperature might not be below freezing...... but the heat-pump controller thinks it is.That's what triggers the BUH. Why not jus...
Disabling a feature could just be masking a poor solder joint in a connection to a sensor! Wouldn't it be better to narrow down the search first bef...
Whatever we're looking for is an intermittent fault.It occurs, and then goes away. If you look at the display a few hours later, everything might ap...
It doesn't matter what the manual states about the BUH operating only rarely.That's just declaring what it's meant to do.But we're looking at a fault ...
Do you have any record of the DHW tank temperature during these night-time antics? 240-litres looks like a great place to dump a shed-load of energy...
Ok. I'm just checking whether there was any manual intervention at 8am-ish on Friday.As you say that there wasn't, then something has occurred to knoc...
Are those yesterday's readings?Or last Friday's? What 'event' occurred at 8am which might account for the sudden drop in electricity usage?
And what perceived benefit does one get from spending £550-ish on such a pump?! Wilo's technical spec suggests that it doesn't run at -9°C but I'm...
- 26 Forums
- 2,158 Topics
- 47.4 K Posts
- 29 Online
- 5,736 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Heat Pump Damage on install - useable or dealbreaker?
They have already been dishonest by not telling you abo...
By GrahamF , 2 hours ago
-
Testing new controls/monitoring for Midea Clone ASHP
Hi all, I thought it might be of interest to others i...
By benson , 2 hours ago
-
-
RE: Electricity price predictions
@diverted-energy sounds like good tariff for you. Octop...
By JulianC , 3 hours ago
-
RE: Who’s Caved and Switched the Heating On Already?
In the last week, the external temperature in south Man...
By GrahamF , 5 hours ago
-
Ok. Two schools of thought. The first is to run the ...
By JamesPa , 6 hours ago
-
@drei Willing as I am to help, I don't think I'm yet ...
By JamesPa , 6 hours ago
-
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?
I hear you on the locality issue @transparent, and I ag...
By Scalextrix , 8 hours ago
-
Selling 5 year old ASHP & Gas Combi Boiler - £590
Selling a 5-year-old Daikin Altherma Hybrid Air Source ...
By Paul G , 9 hours ago
-
RE: Midea ASHP – how to set weather compensation
@pash44pump Referring to the problem of rooms with diff...
By Tasos , 10 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
Er true, it should have read l/hr!
By JamesPa , 11 hours ago
-
@damon thanks. I will do as you suggest. Hopefully I wi...
By bontwoody , 1 day ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Much of that is true in principle, but its not likely t...
By JamesPa , 2 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@dgclimatecontrol I attach the responses from 2 potenti...
By pash44pump , 2 days ago
-
RE: Buffers, hot water and cooling
@dgclimatecontrol thanks, that's helpful.
By JamesPa , 3 days ago
-
RE: Failing heat pump system - seeking thoughts on a rebuild
I realise im overdue an update on my situation. first...
By Cleardene-ashp , 3 days ago
-
RE: Replacing Worcester oil boiler with an ASHP
@toodles thanks. I was told by the engineer that this h...
By JulianC , 3 days ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
A week later, I'm finally picking up this comment... ...
By Transparent , 3 days ago
-
RE: COP is not the only measure of efficiency
We keep all our TRVs fully open using the whole house a...