Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Apr 7, 2026
I would be very interested in hearing more about your conversations with the trade about ASHP installations. We have had the original installers back ...
I had the unit set to 18 overnight (till 4am) and 19 from then on but this morning at 6am the temperature in the house was down to 17.5C It had not ri...
I failed to say that the design allows for a 50C flow temperature but since the engineer did some fettling I have not investigated it again.
@gfkw1947 I don't think that there has been a decrease in efficiency. I know I should be able to find the data on the efficiency but I do not know how...
@sapper117 I have set it to increase the temperature from 17C to 20C at 4am. It reduces again at 8pm.
Forum Handle: timatheronwood Manufacturer: Daikin Model: 3HT HT_767 High Temperature split (R32) Type: ASHP Arrangement: Split, High Temp, Biv...
@kev-m The Daikin engineer came out and installed two back up heater units under warranty as they had not worked from the start. Our problem with t...
SO the Daikin people called back and asked me to reset the thermostat from 20 to 23 to increase the requested load on the system. Success! The system ...
We had a Daikin Altherma 3 High Temp Split HHT (R32) installed in November 2021. It has never functioned well. We have had three Daikin engineer visit...
Hello everyone! We have a Daikin ASHP - Altherma 3 High Temp Split HHT (R32). We have had a number of issues with the unit unable to keep heating th...
- 27 Forums
- 2,758 Topics
- 64.9 K Posts
- 694 Online
- 7,162 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Where heat loss surveys seem to go against practical reality
I am amazed that there is not something out there to me...
By JamesPa , 23 minutes ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
@bobflux The hydraulic simulator is very interesting...
By Rob of York , 6 hours ago
-
RE: 7kW EV Charger Options Advice
Thanks. Yes, we have patchy 4G. The only option we had ...
By Rusty , 11 hours ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 1 day ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@batpred I suspect it will be more this year. I had 9 ...
By AndrewJ , 1 day ago
-
RE: Surface mount or bury primaries for heat pump installation?
@jamespa It's rusting 🙂
By tomasmcguinness , 1 day ago
-
RE: Glass lined Cylinder for private water supply
Thank you, once again, for your replies. Yes...
By ian33a , 1 day ago
-
It’s been out a few days and Amazon has already attache...
By Mars , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes, and this is another point I agree. We did find a f...
By Batpred , 1 day ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
A very good point. In effect, the DHW pipework is an em...
By cathodeRay , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@tim441 Here are those same three month periods for 202...
By Toodles , 3 days ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
@transparent thank you for your reply above. As alway...
By Old_Scientist , 4 days ago
-
RE: Adventures in heat loss calculations
@rob-of-york — thanks for posting this, all very useful...
By cathodeRay , 6 days ago