Last seen: Mar 8, 2023
I would be very interested in hearing more about your conversations with the trade about ASHP installations. We have had the original installers back ...
I had the unit set to 18 overnight (till 4am) and 19 from then on but this morning at 6am the temperature in the house was down to 17.5C It had not ri...
I failed to say that the design allows for a 50C flow temperature but since the engineer did some fettling I have not investigated it again.
@gfkw1947 I don't think that there has been a decrease in efficiency. I know I should be able to find the data on the efficiency but I do not know how...
@sapper117 I have set it to increase the temperature from 17C to 20C at 4am. It reduces again at 8pm.
Forum Handle: timatheronwood Manufacturer: Daikin Model: 3HT HT_767 High Temperature split (R32) Type: ASHP Arrangement: Split, High Temp, Biv...
@kev-m The Daikin engineer came out and installed two back up heater units under warranty as they had not worked from the start. Our problem with t...
SO the Daikin people called back and asked me to reset the thermostat from 20 to 23 to increase the requested load on the system. Success! The system ...
We had a Daikin Altherma 3 High Temp Split HHT (R32) installed in November 2021. It has never functioned well. We have had three Daikin engineer visit...
Hello everyone! We have a Daikin ASHP - Altherma 3 High Temp Split HHT (R32). We have had a number of issues with the unit unable to keep heating th...
- 26 Forums
- 2,360 Topics
- 53.5 K Posts
- 149 Online
- 6,026 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Mitsubishi Ecodan R290 10kW performance
@sheriff-fatman This is the table that I am familiar wi...
By Ecoste , 4 hours ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron, I'm looking into this for you... from my own pe...
By Mars , 6 hours ago
-
RE: New Fogstar 15.5kWh upright solution
SITREP #5 (I think) Milestone completed toda...
By GGW , 8 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 8 hours ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 8 hours ago
-
RE: Speedcomfort radiator fans
My take on Speedcomfort radiator fans: If anyone w...
By Mars , 14 hours ago
-
RE: Midea ASHP – how to set weather compensation
@pash44pump I have yet to come across any Clivet or Mid...
By benson , 15 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 15 hours ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 15 hours ago
-
RE: Home Assistant vs ESPAltherma.
@majordennisbloodnok Thanks very much.
By Ubert767 , 16 hours ago
-
RE: Setback savings - fact or fiction?
I could, but I think we can do better, by plotting hour...
By cathodeRay , 1 day ago
-
RE: Advice on internal circulation pump noise
Extend the primary branch and make sure you have more t...
By ASHP-BOBBA , 1 day ago
-
RE: External pipework insulation
Oh Dear! that's appalling pipe work, should've been in ...
By dgclimatecontrol , 2 days ago
-
RE: Jokes and fun posts about heat pumps and renewables
By Morgan , 2 days ago
-
RE: Controlling Daikin Altherma via P1P2 and Home Assistant
On the contrary, @toodles, that’s a lot of help. I’d ne...
By Majordennisbloodnok , 2 days ago
-
Parsnip, Bacon & Coconut Milk Soup
First let me say, I am only a cook because I am human a...
By Toodles , 2 days ago
-
RE: Electricity price predictions
Ben Watts posted on LinkedIn that he had updated this w...
By Judith , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
Small update, Emailed and Spoke to Midea UK and they ...
By Burtis , 3 days ago