RE: Testing new controls/monitoring for Midea Clone ASHP

I don't think I am. The order is: 1. The system orders a defrost cycle. 2. The OAT sensor sends erroneous measurement (warmer). 3. The set LWT (...

2 weeks ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Ha, ha true, but I am not saying it isn't any good, I am saying it is not that good. A simple argument is that it is open loop. And to answer your "an...

2 weeks ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@benson T1S is actually the LWT defined by the WC. However, I wouldn't describe the behavior as "overshooting", but rather "oscillating" around the se...

2 weeks ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

The refresh time of climate-related curves in heating mode can be changed but not less than 0.5 hrs. This explains the LWT behavior. Further, since ...

2 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

@pash44pump Referring to the problem of rooms with different heating demands, I would use a recently available option which is thermostatic valves wit...

3 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

@cathoderay OK let's wait and see, it sounds an interesting exercise.

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

@benson I believe, noting the data in 16 hourly intervals should be more than enough for the purpose we are discussing (after the system has been work...

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

@pash44pump My opinion on data collection is the following: Regarding OAT, I would use the pump's sensor, since it is this value that the system use...

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

(a) The thermostat will work only if you exceed the desired temperature (in case WC does not work properly), to save you money. (b) if you want inde...

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

WC is more stable because it modulates the inverter and thermostat based control has, currently, on-off behavior. It is not the information that is wr...

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

Here is the manual: In any case there is no point in continuing this discussion, as it is not going to help our friend. If he can be happy with w...

4 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

I think we are talking about the same type of Midea heat pumps. I attach the operation manual of mine, which in Section 10.2.5, p. 59, states what I a...

4 weeks ago