Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

sjn
sjn
@sjn
Member
Eminent Member
Joined: Mar 25, 2024
Last seen: May 4, 2025
Topics: 1 / Replies: 22
Reply
RE: Increase floor temps for UFH, Samsung Gen6

@andehh, do you have a way of monitoring the power being produced by the ASHP when the UFH is on or, failing that, can you check the Instantaneous Usa...

1 year ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

@jamespa thank you for your helpful comments. It has been very useful for me to write all this down and for someone else to sanity check it in case I ...

1 year ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

@jamespa - thank you for your comments. The plot of the compressor frequency is very interesting. Before I had the instrumentation sorted out I was ...

1 year ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

It is a 4 port buffer. Yes, there is a secondary pump on the UFH return to the buffer. The initial install included yet another pump on the sec...

1 year ago
Reply
RE: Sudden drop in COP

@ecobaker Yes, it must have been a software bug disrupting my historic energy numbers. I haven't looked at them recently so I should check to see if t...

2 years ago
Reply
RE: Sudden drop in COP

@ecobaker, How do the energy use and generation output differ between the good COP and bad COP weeks? Is it that the energy used has increased o...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@derek-m This has always confused me. The only way to change the FSV parameters I have found on my Gen 6 Wired Remote Controller is the Installat...

2 years ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@lokisam, with the 20C outside air temperature I would think that the ASHP would not be working too hard so it is concerning that your readings are st...

2 years ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@editor yes, the more I read the forum posts the more I realise that the Samsung issues tend to be the more challenging sort. The various manufactur...

2 years ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@elton that's a cunningly devised methodology 😀 . As a self selecting group the visit a heat pump list will probably give a very accurate refl...

2 years ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

Thanks @lokisam We've been lucky over the last week with day temperatures in the 20s and night temperature only down to 11C so haven't had the heat...

2 years ago