RE: Increase floor temps for UFH, Samsung Gen6

@andehh, do you have a way of monitoring the power being produced by the ASHP when the UFH is on or, failing that, can you check the Instantaneous Usa...

2 months ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

@jamespa thank you for your helpful comments. It has been very useful for me to write all this down and for someone else to sanity check it in case I ...

2 months ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

@jamespa - thank you for your comments. The plot of the compressor frequency is very interesting. Before I had the instrumentation sorted out I was ...

2 months ago
Reply
RE: More Samsung weather compensation oddities (8kW Gen6)

It is a 4 port buffer. Yes, there is a secondary pump on the UFH return to the buffer. The initial install included yet another pump on the sec...

2 months ago
Reply
RE: Sudden drop in COP

@ecobaker Yes, it must have been a software bug disrupting my historic energy numbers. I haven't looked at them recently so I should check to see if t...

8 months ago
Reply
RE: Sudden drop in COP

@ecobaker, How do the energy use and generation output differ between the good COP and bad COP weeks? Is it that the energy used has increased o...

8 months ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

@derek-m This has always confused me. The only way to change the FSV parameters I have found on my Gen 6 Wired Remote Controller is the Installat...

8 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@lokisam, with the 20C outside air temperature I would think that the ASHP would not be working too hard so it is concerning that your readings are st...

8 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@editor yes, the more I read the forum posts the more I realise that the Samsung issues tend to be the more challenging sort. The various manufactur...

8 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

@elton that's a cunningly devised methodology 😀 . As a self selecting group the visit a heat pump list will probably give a very accurate refl...

8 months ago
Reply
RE: Noise problems with newly installed Samsung 8kW ASHP

Thanks @lokisam We've been lucky over the last week with day temperatures in the 20s and night temperature only down to 11C so haven't had the heat...

8 months ago