Things didn't quite go to plan with the install... They can't start this week, but rather next week, so that's a whole extra week without heating. We'...
@alec-morrow Yes the boiler is completely shot, so no point doing a step-by-step change at this point. The installers have confirmed that they'll b...
@alec-morrow Why would you particularly seek out a controller that can control both? I don't foresee running both at once, and I am hoping that now...
I just got back from a lovely warm holiday in a different part of the world to a broken boiler! I turned the heating up a day before we flew back home...
@derek-m Hi Derek, thanks for the post. I thought of that, hence why I thought if the radiator that needs to provide the most heat has 15mm pipes ...
@robl I appeciate the maths here, but I feel that with all the uncertainties stacking with a real life measurement, it might come out worse than the a...
It does sound quite ambitious, but I think it should be fine so long as you take measures to protect yourselves. What happens to the deposit if the ...
The results are in, and using a calorific value of 39.5 (my meter is in m3) and a flow temp of 70C, it started on about 18kW of gas usage, then settle...
28mm pipe can carry 16.8kW of power if the difference in temperature between flow and return is 5C, which it probably is. This means that assuming the...
That's exactly it. I fear that in the ASHP world, if you don't know at least as much as the person selling you it (assuming they're a sales person), y...
I appreciate the vote of confidence! However, I don't think I dare go outside of MCS installations because it gives me recourse if something goes wron...
I guess this is true, but it depends how well the heatpump can modulate its compressor/flow rate. Most, it would appear to me, do not modulate all tha...
- 26 Forums
- 2,406 Topics
- 54.6 K Posts
- 382 Online
- 6,092 Members
Join Us!
Worth Watching
Latest Posts
-
We are 2 weeks away from our HP install. In October I...
By Bash , 2 minutes ago
-
RE: Experience - New Build / Complete New Heating System
Welcome to the forums @vincro and good luck with finali...
By Mars , 3 minutes ago
-
I’m glad the cold spell is over!
Just a sigh of relief that the cold spell is over and t...
By Judith , 14 minutes ago
-
RE: Heat pump not reaching flow temperature
@jamespa the compressor does run at max operating frequ...
By DaveC , 16 minutes ago
-
RE: Post-Traumatic Heat Pump Stress Disorder
@johnbroome As I say I think you probably have a fau...
By JamesPa , 27 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
So far as i can see no because its NOT connected to the...
By JamesPa , 2 hours ago
-
RE: Please help with the settings ecodan
Hi and welcome to the forums.Does your system use a Mit...
By Sheriff Fatman , 2 hours ago
-
RE: New Daikin 11kW Altherma 3M install - is it working as it should?
I forgot to mention: Octopus measured our heat loss at ...
By Toodles , 3 hours ago
-
RE: Considering MLCP (Multi-Layer Composite Pipe) for ASHP
Thanks Mars and thank you for reaching out to so many p...
By iotum , 3 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: @davec Manufacturer: Peak Energy Mode...
By DaveC , 3 hours ago
-
RE: Rate the quality of your heat pump design and installation
@radwhispererdwhisperereorourkeditor Well, the guy came...
By razz , 3 hours ago
-
RE: Setback savings - fact or fiction?
Given the weather has been relatively stable, the empir...
By Batpred , 4 hours ago
-
RE: GSHP WOES! Midland based engineer recommendations?
@editor That is very kind! Thank you so much.
By johnbroome , 5 hours ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@wally Hi I am not sure how large your house is b...
By TechnoGeek , 6 hours ago
-
RE: Predicted Heat Loss & Needs from MCS calcs vs EPC vs actual
I've been thinking along similar lines to @tim441 from ...
By Sheriff Fatman , 7 hours ago
-
Thanks, @technogeek. Good to hear about the accuracy. ...
By Majordennisbloodnok , 7 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
In my case it was a very specific pattern of behaviour ...
By Sheriff Fatman , 7 hours ago
-
RE: Vaillant aroTherm not heating with many faults
@ashp-bobba Yeah I'll give it a go, will check filter...
By Anon67 , 8 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Perhaps the names at the end of the docume...
By Toodles , 8 hours ago