I changed mine a while back to just heat from 2-3pm, have no lower set point so sometimes its heating 300l tank from below 30, would it be wise to put...
part of the reason why im using fixed flow temp, with wcc sometimes it takes alot longer to heat after setting back overnight.
The kitchen gets to 23, all tiled floor and other living areas 22, while bedroom's 21. I actually lowered flow temp to 29 for today and i will check u...
All depends on the house, i timed my unit to go off at 9pm last night, house was still 21 degrees this morning. Heating due to come back on at 2pm. I ...
Not sure i understand, when i set back my stat to 18deg at 9pm, my unit goes off until 2pm following day, its not running/cycling as i can see no elec...
Is programmable thermostat not your answer. I have one in the house ,i have it set above desired temps for when i want heating, 2-9pm and set to @18 ...
Personally going totally against the grain here but i have now set a fixed temp of 30degrees and im running for 6 hours from mid afternoon to 8pm. So ...
@derek-m Thanks man, feel more optimistic in my hp now. Also the flow rate is often above 30 it modulates a bit. I just don't get the continuous concl...
@derek-m How did you work out what thermal energy i was producing from them screen? actually no cycling at all, flow modulating abit at times but not ...
@derek-m Yes i have meter for heat pump in fuse box and smart meter outdoors, they pretty similar for past hour usage. No nothing else that would use ...
Thanks lads, house stays warm when up to temp so dont think i have massive heatloss. Attached is ber cert i got for house, think heat loss calc is in ...
With last week of heating, if my daikin is correct im getting cop of 6, which is Great, however im using 2kwh per hour usage or close to it, this is l...
- 26 Forums
- 2,102 Topics
- 46.2 K Posts
- 121 Online
- 3,388 Members
Join Us!
Latest Posts
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
@skyefarmer great you located the source of the issue a...
By Mars , 4 hours ago
-
RE: Location of hot water isolation valve on cylinder
@rossowheels if you isolate the water supply in it will...
By ASHP-BOBBA , 13 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
From what you say about the radiators upstairs it does ...
By JamesPa , 19 hours ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 21 hours ago
-
@heacol, if you're around, can you please provide some ...
By Mars , 1 day ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 1 day ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 2 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 2 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 2 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 2 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 3 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 3 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 3 days ago
-
If you are thinking of heating on the immersion conside...
By JamesPa , 4 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness, I think your best bet would be using ...
By Aventus Eco , 5 days ago