What does one of these PHE's look like and why would you chose one over and buffer tank? I believe my Midea system has a direct buffer tank with the...
@cathoderay Yeah you would think a 16kw and a smaller one would be the way to go but the installer normally installs only Vaillant but couldnt get the...
My installer seemed to have clocked that the 16kw really was only 13.5kw when compared to other brands (I havent looked at the data Midea provide too ...
@batalto Ours stopped doing it as and when the temp of the DHW dropped x below the set point , hence I had to use the timer to ensure it worked now th...
@batalto But do you have problems with hot water not being available, ours was 34 degrees this morning having not heated up over night like it should ...
@grahamh Last night the ASHP produced no DHW. Having reverted to DHW on a timer this usually works but not last night (I believe the temp dropped to a...
Think it was called MiCloud or Mycloud, but you can only get it from the direct or through your installer.
@batalto I believe they have an app developed by Freedom that they consider is for the installers, forgotten the name of it but its not on the app sto...
@grahamh It could be at 29 degrees for 6-7 hours and still not kick in, if it was only 90mins which I think its set to it wouldnt be an issue. Even a ...
@grahamh Hi Graham, I have one question for you. Our Midea ASHP is set the DHW as a priority and should kick in anytime the temp drops 10 degrees belo...
@derek-m Ah ok, yes my intention is to do as you describe. But I did think that feedback of the space temp to the controller would help it adjust flow...
@derek-m I presume by true temp compensation you mean having a sensor in the area being heated thats connected back to the ASHP controller. Therefore ...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 295 Online
- 6,027 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Speedcomfort radiator fans
@mars I think you say somewhere in the video that fans ...
By JamesPa , 26 minutes ago
-
RE: Mitsubishi Ecodan R290 10kW performance
Sorry I dont know the answer to that as I dont have a M...
By JamesPa , 38 minutes ago
-
Sadly, no, @agentgeorge. The inverter will handle 5kW t...
By Majordennisbloodnok , 11 hours ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent The readings are 0 for amps, 0 ...
By Batpred , 11 hours ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 12 hours ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 13 hours ago
-
RE: Setback savings - fact or fiction?
Will come back to the above points, but for now, I've j...
By cathodeRay , 13 hours ago
-
@jamespa I have found that it comes as a shock when we ...
By Toodles , 15 hours ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
I suspect a good chunk of the "losses" are power consum...
By Bash , 16 hours ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Hi @mickamills . Welcome to the forum. It sounds like...
By bontwoody , 17 hours ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 17 hours ago
-
RE: External pipework insulation
@transparent I hope you are not being admonished @trans...
By Toodles , 17 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 2 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 2 days ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 2 days ago
-
-
RE: Advice on internal circulation pump noise
Extend the primary branch and make sure you have more t...
By ASHP-BOBBA , 3 days ago