What does one of these PHE's look like and why would you chose one over and buffer tank? I believe my Midea system has a direct buffer tank with the...
@cathoderay Yeah you would think a 16kw and a smaller one would be the way to go but the installer normally installs only Vaillant but couldnt get the...
My installer seemed to have clocked that the 16kw really was only 13.5kw when compared to other brands (I havent looked at the data Midea provide too ...
@batalto Ours stopped doing it as and when the temp of the DHW dropped x below the set point , hence I had to use the timer to ensure it worked now th...
@batalto But do you have problems with hot water not being available, ours was 34 degrees this morning having not heated up over night like it should ...
@grahamh Last night the ASHP produced no DHW. Having reverted to DHW on a timer this usually works but not last night (I believe the temp dropped to a...
Think it was called MiCloud or Mycloud, but you can only get it from the direct or through your installer.
@batalto I believe they have an app developed by Freedom that they consider is for the installers, forgotten the name of it but its not on the app sto...
@grahamh It could be at 29 degrees for 6-7 hours and still not kick in, if it was only 90mins which I think its set to it wouldnt be an issue. Even a ...
@grahamh Hi Graham, I have one question for you. Our Midea ASHP is set the DHW as a priority and should kick in anytime the temp drops 10 degrees belo...
@derek-m Ah ok, yes my intention is to do as you describe. But I did think that feedback of the space temp to the controller would help it adjust flow...
@derek-m I presume by true temp compensation you mean having a sensor in the area being heated thats connected back to the ASHP controller. Therefore ...
- 24 Forums
- 1,427 Topics
- 30 K Posts
- 49 Online
- 1,213 Members
Join Us!
Latest Posts
-
RE: Insulation of flow and return Heat Pump piping
@mike-h Thanks Mike. Toodles.
By Toodles , 37 mins ago
-
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?
@david999 What size is your Samsung? Is it 16kW? If not...
By Mike H , 48 mins ago
-
RE: Bivalent (or even trivalent!) system design options for a new GSHP installation
For your interest @algienon this is what happens when a...
By Transparent , 2 hours ago
-
RE: Rising Damp – Production Recommendation
Yet another topic I'm not an expert in. Nonetheless, th...
By Majordennisbloodnok , 5 hours ago
-
RE: Noise problems with newly installed Samsung 8kW ASHP
@editor yes, the more I read the forum posts the more I...
By sjn , 7 hours ago
-
RE: Observations on my Ecodan's estimates of energy consumed and delivered
As it is possible for the FTC to be powered from a sepa...
By HarriUp , 16 hours ago
-
RE: ASHP Cut-off Temperatures: What's Your Setting and is a Your Heating Still On?
My system has been running 24/7 on weather compensation...
By HughF , 18 hours ago
-
RE: Heat Pump Truth or Myth#2 - Cycling uses a lot of power and ruins your COP
I cannot state that I have noticed that our A2A heat pu...
By Derek M , 21 hours ago
-
RE: Maximising Savings: Navigating My First Year with Octopus Energy and Heat Pump Running Costs
@toodles I can also happily report that the Agile tarif...
By Steve D , 22 hours ago
-
@editor As we all know, RHH always strive to educate, e...
By Toodles , 24 hours ago
-
@bontwoody I used the website link to contact them for ...
By Toodles , 1 day ago
-
RE: Samsung ASHP power cycling
I have considered that and I would have expected to see...
By Blaine_t , 1 day ago
-
RE: 14kW Midea ASHP in an old leaky building
Hi @batalto. I see you have a Midea ASHP and I am sched...
By Kbedders , 1 day ago
-
RE: Additional ASHP kW for DHW cylinder?
We're in a similar boat to you with a hodgepodge of dif...
By Mars , 1 day ago
-
RE: No-code, plug-and-play monitoring for your heat pump
Anyway, so far we have all missed the main protagonist ...
By Toodles , 1 day ago
-
RE: Are Octopuses Slowing Consumer Adoption of Heat Pumps?
@ivanopinion Im in the same team as Ivan. I think for a...
By bontwoody , 2 days ago
-
RE: Issues with Vaillant connectivity via the MyCONNECT gateway
@drew-pa I don't know about hard work! It is pretty cl...
By dr_dongle , 3 days ago
-
RE: Are Solar Diverters Necessary for Homes with ASHPs and Solar PV?
@editor No, I made one 😀 Loft insulation all...
By Andris , 4 days ago
-
@hughf Thanks for that. Ah so they are talking about ...
By IRMartini , 4 days ago
-
RE: Ecodan software update. Real or scam?
@abernyte, hmm, must have been a major disruption if 40...
By Mars , 4 days ago
Latest Topics
-
By Toodles 1 day ago
-
By Blaine_t 1 day ago
-
Insulation of flow and return Heat Pump piping
By Toodles 1 day ago
-
Rising Damp – Production Recommendation
By Mars 1 day ago
-
Additional ASHP kW for DHW cylinder?
By Project_Electrify 2 days ago
-
By IRMartini 4 days ago
-
Riello / Midea - modbus set flow temp
By stuartornum 5 days ago
-
Ecodan software update. Real or scam?
By Morgan 5 days ago
-
Noise problems with newly installed Samsung 8kW ASHP
By Lokisam 1 week ago