ASHP ran on until outlet temp reached 64. The lights on zone valve boxes above show neither were calling for heat.
The pump came on again early this morning. I took more pics but I can't see any clues apart from "Thermostat 1" being "on" in Zone status info ?
@iancalderbank Thanks. Seen PM but cant reply to them yet 🙂 thanks
Many thanks. I would love to come and collect. How do you want to arrange this ? (donation to MS Society if that's OK with you, son has MS)
DOH .. I have just realised what FTAGH means 😊
@iancalderbank Thanks for the reply. I'm in Worcester but ........ How much do you want and what is included ?
early days as you say. Yes, I have all the manuals and was given hand overs ............. tbh maybe a bit basic but I'm working my way through the c...
Thanks First, I'll confirm that IUD is stored elsewhere with no spiders ! Second, yes, the issue is no connection to Shell (who did install the me...
Shell can't connect to my meter (WR135DW). The IUD works OK but it can't "pair to the account". I guess the oblong thing with cable is an aerial? Sh...
Hello 🙂 We have just had ASHP/PV/Internal insulation fitted under the ECO4 scheme. Qualifying conditions where one household member on Universal...
- 27 Forums
- 2,484 Topics
- 57.3 K Posts
- 614 Online
- 6,196 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Warranty Repairs- An Un Eddi fying experience!
@editor Did you have one of the really old ones with th...
By swwils , 2 hours ago
-
RE: Brine pump error message on Thermia 8kW ground source heat pump system
@schanna I’ve just DM’d you a potential company that’s ...
By Mars , 3 hours ago
-
RE: Tell us about your Solar (PV) setup
Actually not that far, however, the cost of my...
By upnorthandpersonal , 3 hours ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
@petch I’ve not come across anyone yet that’s used thes...
By Mars , 3 hours ago
-
RE: Hoped for improvements not being realised on my Mitsubishi heat pump
Steady green means that the pump is running full speed....
By smsm1 , 3 hours ago
-
RE: Help…my NIBE heat pump has faulted again!
@jamespa I meant to say I attached the report from the ...
By Fiona , 4 hours ago
-
RE: Rate the quality of your heat pump design and installation
I don’t have the strength to post this tonight, but I’v...
By Mars , 4 hours ago
-
Vaillant app under reporting flow temperature
Our Vailllant 5kW heat pump is working well and the hou...
By Bengeo , 4 hours ago
-
@boycey, in your scenario if you use Melpump to change ...
By Majordennisbloodnok , 8 hours ago
-
RE: A Smarter Smart Controller from Homely?
Yep- already done that....nothing novel as such but som...
By benson , 9 hours ago
-
RE: Help needed to adjust weather compensation on Vaillant air source heat pump
I am in the fortunate position of having independent mo...
By MartinRobinson , 9 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@swwils Similar here, though it has been very mild. I...
By KevH , 11 hours ago
-
RE: Home energy storage & battery register
@toodles thankfully we have a range of tariffs to meet ...
By TechnoGeek , 13 hours ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@editor thanks Mars! I'll contact them.
By kevinmc1970 , 15 hours ago
-
RE: Noisy Grant Aerona 3 13kW ASHP question
@heymikey thanks for the update and sorry to hear that ...
By Mars , 1 day ago
-
RE: Heat loss calculations and how they work in conjunction with heat pump sizing
@jamiejones85mespa your comments are spot on with my th...
By AgentGeorge , 1 day ago
-
RE: The good, the bad and the not that great – my heat pump installation
Must of knocked a load of crud through when they added ...
By Burtis , 1 day ago
-
@mkz, yes I have other installers... can you please sen...
By Mars , 2 days ago
-
I should add that our survey came up with a heat loss o...
By MartinRobinson , 2 days ago
-
RE: Optimising LG Therma V R32 using AI
@bontwoody oh dear! ... but as you say.. I suppose th...
By Tim441 , 2 days ago
-
RE: Volumiser required on Grant R290 air source heat pump?
@judith Indeed it's similar to the UK. It has to be an ...
By Patrick , 2 days ago
-
RE: Say hello and introduce yourself
Underfloor hydronic, powered by both the heat pump and ...
By upnorthandpersonal , 2 days ago
-
RE: PV export revenue and HMRC
That makes sense. They are companies that are on market...
By Batpred , 2 days ago
-
RE: R290 Heat Pump and Foundation Air Bricks
I have been having fun and games whilst getting surveys...
By petch , 2 days ago
-
RE: Ideal HP290 14kW ASHP - how to optimise
@ashp-bobba brill thanks again!