It hasn't been announced yet but I believe it will be credited to the electricity accounts of those who don't have gas. The 'don't have gas' bit is a ...
Hi and welcome. Sorry to hear of your problems. I can't help with 1. That is something the installer would have to sort out and sounds like a design...
I have an Ecodan with 2 expansion vessels and I definitely have no buffer or LLH. @sunandair, good news on getting the FTC6 replaced.
I think it's something that might be of some interest. I'm always amazed by the audacity of criminals and the risks they take for relatively little g...
If you look at the front panel of the main controller, WC has a +-0, Fixed will have whatever you set the flow at (e.g. 45) and room temp will have th...
I suspect the legally sound way (assuming the OP has a contract with the installer and not directly with Nibe) is to ask the installer to install an a...
Mike, it depends on the ASHP. In the Ecodan, it's hard wired based on a particular sensor being below -X degrees for Y minutes (or something like th...
I haven't tried scheduling via the app; I do mine using the main wired controller and just use the app to view. It does look like some sort of loss o...
Well in a newish house I'd try something like 45 -5 and 20 15 to start with. To test whether that's right, turn the thermostat to 2 or 3 degrees more...
Hi Will and welcome. If you start a new thread in the ASHP section and include some details about your house and ASHP someone will be able to help.
10 minutes. I'd never looked before. It prompted me to limit the ASHP's LWT to 48 degrees. It was 55 and it has been that high a few times (auto adap...
It's better in warmer weather. Less cycling and a smoother, less spiky start up in the morning. My tool for analysing the data is playing up but ...
- 22 Forums
- 2,086 Topics
- 46 K Posts
- 30 Online
- 3,377 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness bold choice on the Kronoterm. Nice! Wi...
By Mars , 4 hours ago
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
It took me more than a few goes as well, plus some help...
By cathodeRay , 20 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
@ashp-bobba thank you, and equally so, thank you for ta...
By Mars , 1 day ago
-
@judith good to know… I’ll continue to feed Wattson, an...
By Mars , 2 days ago
-
RE: Vaillant AroTherm Plus 7kW
@jamespa I have a hydronic baseboard heater in the kitc...
By Scalextrix , 2 days ago
-
RE: My misgivings about installing ASHP and solar panels via the ECO4 scheme...
@editor great article re accreditation. I note ISO/IEC ...
By Bart , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Here’s a little more technical detail/p>
By Judith , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
I don't (yet), but my PW3 is due to be installed shortl...
By Old_Scientist , 3 days ago
-
RE: MCS and NAPIT complaints process
@chrislay, is your heat pump complaint still unresolved...
By Mars , 3 days ago
-
RE: ASHP Install from hell - help please
@saf1973 I’ve been going through old cases on the forum...
By Mars , 3 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@aaron There's the rub, the database does not list my ...
By AF1 , 4 days ago
-
RE: Commencing on an ASHP Installation Process
Yes, it's "doable" if everything goes to plan, they arr...
By Old_Scientist , 5 days ago
-
RE: How not to install a heat pump
You are right. Thinking on this has evolved over the p...
By JamesPa , 6 days ago
-
RE: DHW SET UP with Samsung gen 5
Thats good news indeed, you are very likely almost ther...
By JamesPa , 6 days ago
-
RE: Plate heat exchanger considerations
As far as I can tell my vented system would have a peak...
By Scalextrix , 6 days ago
-
RE: Air Changes per Hour - ACH and the MCS requirement
There have been a few discussions dotted around (e.g. I...
By Declan90 , 6 days ago