Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 8, 2025
I missed that about the new radiators. I had all new rads and pipework fitted (I had no central heating before) and it was about £4.5k extra for every...
@Katcesca, Hello and welcome. I think you've summarised the issue very well. You're comparing heating some of the house some of the time with all ...
I'm not exactly sure what nominal is; I think it's the compressor speed its official ratings are done at. P55 of the data book gives some info. Min i...
@bialk An 8.5kWEcodan will be able to modulate down to 3-4kW at your flow and ambients. Have a look at page A-57 here. If it takes yours less ...
My 14kW Ecodan can modulate down to 30-35% of its nominal output. Mine will start to cycle at about 10 degrees ambient, sometimes a little more. As ...
Firstly, Melcloud isn't great at controlling the Ecodan. I don't know where the -39 comes from but you can set where the room temperature is monitore...
Some more information required, as a start: Are you running in Weather Compensation mode? What is the outside temperature where you are? Have ...
If ASHPs are to be mass-market it has to be a version of B. but with some expectation management included. Hardly anyone tinkers with their car a...
@marvinator80 looks like you could squeeze in some 12mm ply?
On one of the other heat pump forums, a chap has taken all the COP data from a 11.2kW Ecodan, and the degree days data from where he lives and modelle...
Hi Sali, good to hear you made some progress. I think once you have all the pumps and valves sorted out things should be better. I'm afraid I know...
Sali, this is mine; running steadily then doing a defrost. You can see the 4-5 degree gap and the delay in return following flow. BTW I'm doing s...
- 26 Forums
- 2,622 Topics
- 61.2 K Posts
- 1,293 Online
- 7,003 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
I'll suggest the brown gunge is a thread sealant such a...
By Transparent , 13 minutes ago
-
RE: Heat Pump Pipe Sizing Question
@editor I ran the calculator for my 3.5kw with a run of...
By trebor12345 , 39 minutes ago
-
RE: Jokes and fun posts about heat pumps and renewables
That particular Tracking system gets updated as soon as...
By Transparent , 6 hours ago
-
He, he. Yes, I remember HAL very well, but it was still...
By Majordennisbloodnok , 6 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@editor It's available here -
By HarrisonC , 17 hours ago
-
@painter26 i am in Lightwater and midea trained. Sounds...
By Wizard , 19 hours ago
-
RE: Renewables & Heat Pumps in the News
@jamespa, for all I know they did have the coupling and...
By Mars , 22 hours ago
-
@andrewj ... well, clearing gutters is a worthwhile ann...
By colinc , 23 hours ago
-
RE: Anyone concerned about GivEnergy?
Here is the latest communication from GivEnergy regardi...
By txmartyn , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
Can @editor please clarify: Does the Indevolt App com...
By Transparent , 1 day ago
-
@editor I too had a long list of questions, some of ...
By Bash , 1 day ago
-
RE: Tell us about your Solar (PV) setup
3.84kWp of solar on our main South-East facing roof, in...
By Gmuzz , 1 day ago
-
RE: Mitsubishi Ecodan FTC6, Evohome & Economy 7. Getting Two Zones to Work Together
Lets step back. Why do you need/want 2 zones? The hea...
By JamesPa , 1 day ago
-
RE: Vaillant arotherm plus heat pump frost protection
Yes, typically as close to the heat pump as possible. ...
By JamesPa , 1 day ago
-
RE: Our 10 year old Grant heat pump failed
Back in the 70’s and through the eighties, one of my re...
By Toodles , 2 days ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 3 days ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 3 days ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 3 days ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 3 days ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 3 days ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 3 days ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 3 days ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 3 days ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 3 days ago