Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 12, 2026
OK so feed to rads colder than feed to UFH and colder than flow temp from heat pump. Not good, losing efficiency and thus oomph to building. Taking ...
It does feel like you may have a genuine fault, unfortunately perhaps not bad enough to convince the manufacturer easily. Id be tempted to collect ...
All understood. Basically you are planning on creating a recirculating loop. There are a couple of threads running about this with people complaini...
The last bit of that is bad. Thats just badly (well appallingly) designed UFH and most likely the fundamental problem here - half your energy is goin...
Unfortunately COP for DHW will always be lower because it requires a higher flow temp and thats how the thermodynamics work. 52C is high however, you...
Er not sure that is universally true. Mine is cheaper overall to run that my gas boiler would have been, by about 20% or thereabouts. I have radiato...
Firstly you are getting your units mixed up which is a little confusing. kW is power (how fast you are driving), kWh is energy (how far you have gone...
I would bypass the buffer tank in one of flow or return only, it will then act a bit like a volumiser. The problem you have relatively to a tank th...
I agree with all of that. 220 pages is perhaps 210-215 pages too much. Unfortunately there is no substitute for (a) understanding some basics (which...
@davidnolan22 Perhaps you could post some more info about your setup, house and system and WC parameters - you never know it may be possible to diag...
OK. I have 2.8 for DHW and 3.4 for space heating running at an actual FT of about 36. Yours does seem a bit low depending on what FT you were runnin...
Don't forget to increase max ft also. Mine is set to 55, way clear of the curve. I think that might even have been the default.
- 27 Forums
- 2,744 Topics
- 64.4 K Posts
- 1,599 Online
- 7,147 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
This is very helpful, thank you.
By dansus , 5 minutes ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 1 hour ago
-
I am surprised by Vaillant and I would press them on th...
By JamesPa , 1 hour ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s Look forward to making contact soon! Regards, To...
By Toodles , 2 hours ago
-
Flushing system, cleaning and inhibitor
Hi all, I have some questions about flushing my syste...
By Old_Scientist , 7 hours ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 19 hours ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 1 day ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 2 days ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 2 days ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 3 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 4 days ago