Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Jun 15, 2026
Topics: 25 / Replies: 4987
Reply
RE: Struggling to Find a Top Heat Pump Installer? We Can Connect You With the Best Installers in the UK

There seems to be plenty of evidence to support this. My measured loss is consistent with ach of 0.5-1 whereas the mcs calcs default to 2-3. ashp sy...

6 months ago
Reply
RE: Getting the best out of a heat pump - is Homely a possible answer?

yes to both, probably. External controls for ashps (and many modern boilers) are largely superfluous and frequently counterproductive. The possible...

6 months ago
Reply
RE: One Year Review: Grant 13kW ASHP - A Catalogue of Errors

@solenoid it sounds like you are making progress. No need to hurry these things and please feel free to ask any questions.

6 months ago
Reply
RE: How good is the app support for your heat pump?

I think you are right about the ebus stick. It's certainly possible to change at least some of the exposed vaillant parameters through the ha integr...

6 months ago
Reply
RE: Replacing my 18 month old Hitachi Yutaki ASHP

Yes, you can work out a lot from a plot of FT. Interesting that there were both deep and shallow defrosts, for reasons I dont understand.  

6 months ago
Reply
RE: Replacing my 18 month old Hitachi Yutaki ASHP

OK thats a pity it would have been good to see if/how defrost changed as a result of switching off night shift and overnight there would have been ple...

6 months ago
Reply
RE: Replacing my 18 month old Hitachi Yutaki ASHP

My Vaillant was defrosting every 45-60mins overnight (chart shows FT). As you can see it doesnt fully recover from the defrosts because noise reducti...

6 months ago
Reply
RE: Replacing my 18 month old Hitachi Yutaki ASHP

Something odd about this diagram; the refrigerant is moving in the wrong direction for defrost - warm refrigerant from the compressor should be headin...

6 months ago