Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 15, 2026
There seems to be plenty of evidence to support this. My measured loss is consistent with ach of 0.5-1 whereas the mcs calcs default to 2-3. ashp sy...
yes to both, probably. External controls for ashps (and many modern boilers) are largely superfluous and frequently counterproductive. The possible...
@solenoid it sounds like you are making progress. No need to hurry these things and please feel free to ask any questions.
I think you are right about the ebus stick. It's certainly possible to change at least some of the exposed vaillant parameters through the ha integr...
Yes, you can work out a lot from a plot of FT. Interesting that there were both deep and shallow defrosts, for reasons I dont understand.
OK thats a pity it would have been good to see if/how defrost changed as a result of switching off night shift and overnight there would have been ple...
My Vaillant was defrosting every 45-60mins overnight (chart shows FT). As you can see it doesnt fully recover from the defrosts because noise reducti...
Something odd about this diagram; the refrigerant is moving in the wrong direction for defrost - warm refrigerant from the compressor should be headin...
- 26 Forums
- 2,675 Topics
- 62.6 K Posts
- 207 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
For passivehaus btw you also need to consider just usin...
By EtchedPixels , 6 seconds ago
-
RE: Help me keep the faith with my air source heat pump installation
I didn't know about those, they look like good pieces o...
By JamesPa , 3 hours ago
-
@mkz, that's very helpful. Even if Urban Plumber are no...
By Majordennisbloodnok , 3 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 3 hours ago
-
My first question is why bother with the auto balancin...
By JamesPa , 4 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 4 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 4 hours ago
-
I share the same experience as @majordennisbloodnok hav...
By Old_Scientist , 5 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 8 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@jamespa many thanks, definitely i will give the pre...
By ragtime27 , 19 hours ago
-
RE: Heat pump installation quotations
@jamespa I noticed that in the Heat Geek design consult...
By Batpred , 21 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 1 day ago
-
RE: Daikin ESPAltherma and Home Assistant installation
@bash, something we haven't touched on already relates ...
By Majordennisbloodnok , 1 day ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Vaillant arotherm plus 12kW. Installed March 2025. Ex...
By Harebell , 2 days ago