2024 200sqm 7kW 200l UVC 2 new rads, one new fancoil, one existing rad relocated (total 4 rads changed) 16A feed for heat pump already in pl...
A pair of similar tanks one white and one red are expansion tanks. You can tell because they have a filling nipple at the top and only one pipe leadi...
You are almost right and have appreciated the key point ie that energy lost must be replaced (simple minded, and incorrect, thinking says that if you ...
Based on the numbers I think its likely its oversized. Not a disaster but it means it will probably cycle on and off a lot. If does prove to be over...
That sounds high for UFH. Strongly recommend you follow the procedure I outlined upthread and report back. You should hopefully be looking at a flow...
Yes absolutely. Exactly, the manifold has the equivalent of a radiator LSV and a radiator TRV (the actuator) together. With a radiator you a...
Oh definitely. Getting the WC curve optimised is a key part of the commissioning which, realistically, installers cant be expected to do because it n...
Thats an interesting one - as a matter of fact which (is it the Ecodan twin compressor model?) Indeed, loads of 'models' but in fact only one...
True, but the average householder isnt going to do this. Indeed so. Does it even need to happen though? Those who have responded want to 'tak...
You need to follow a process Turn all room/central thermostats up to maximum Set the heat pump to run 24x7 Ensure that the Ecodan is in weather ...
Can you explain this please, the heat pump manufacturers always specify COP according to LWT. The compressed gas must be hotter than the LWT otherwis...
There is absolutely nothing wrong with buffer tanks in principle. The problem lies with the execution which all too frequently, it seems, involves poo...
- 26 Forums
- 2,275 Topics
- 50.9 K Posts
- 85 Online
- 5,936 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Testing new controls/monitoring for Midea Clone ASHP
It has it's uses and there is no way I could have set t...
By benson , 8 hours ago
-
Samsung Gen6 and Havenwise ........
I sourced the Wi-Fi unit (City Plumbing - £122 with 15%...
By Lenny , 8 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Definitely. 8C DT is higher than the default design DT...
By JamesPa , 10 hours ago
-
@jamespa Thanks again for your reassurance. Rob
By Ubert767 , 15 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
Thanks for the suggestion, but farmhouse is grade 2 lis...
By paultheheating , 17 hours ago
-
RE: My DIY Heat Pump installation
This is very kind. However software is not really my ...
By Polar bear , 22 hours ago
-
RE: Request for feedback on where we're at with our quest to get an ASHP or ideas.
thanks, heatpunk looks great, being able to do the calc...
By giryan , 1 day ago
-
RE: Is Your House Warmer Upstairs Than Downstairs?
Why arent you expecting them to make much difference. ...
By JamesPa , 1 day ago
-
@toodles sounds good. I started with cosy but then plug...
By Eliuccio , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It has been just over a year since we changed over to a...
By npru , 2 days ago
-
RE: Finding a Thermostatic Shower Valve That Works with Heat Pump Systems
@morgan I should just have written ‘Mea Culpa’ shouldn’...
By Toodles , 2 days ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
'We learn from history that we do not learn from histor...
By Lawrence Leask FInstR , 2 days ago
-
Mitsubishi Ecodan FTC7 Legionella date set
I can set the number of days between Legionella cycles ...
By DRB01 , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
@treewizard Yes, I like the extra facilities that NetZe...
By Toodles , 2 days ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk downstairs rads are less prone to airlocks, you ...
By AgentGeorge , 2 days ago
-
RE: My Octopus Cosy 6 Heat Pump Journey: From Quote to Completion
@editor thanks for highlighting my name. Yes I did get ...
By Chansug , 2 days ago
-
RE: balancing radiators with a mixture of different size pipework and a few undersize rads.
@editor Thanks for your input Mars. No I think the comm...
By baxtDave , 3 days ago
-
RE: Rate the quality of your heat pump design and installation
We’re looking to expand our list of recommended list of...
By Mars , 3 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Along with the right workers, they can’t b...
By Toodles , 3 days ago