Thanks for the analysis of the capabilities of the various smart TRVs. Its interesting that Wundasmart and Wiser work by PID, which suggests that, wi...
Thats simply not true (to any material extent), which is where you are going wrong!. Essentially you are mixing up cause and effect. The heat outpu...
Understood, but it feels like a no-brainer. As I remarked above b atteries almost make financial sense/already do for some even now!
Not necessarily, wrongly set up it will make cycling worse (sorry, comment refers to buffer not turning up pump speed) The solution is to replumb as...
Yes The problem with buffer tanks (unless they have only 2 ports) is that you get mixing between flow and return, unless the pumps either side are ...
Well found. If that's the case and assuming it's 3 or 4 port not 2 port that could account for another 10-15%. Ideally it needs to go but installers...
Useful. When did it go into shade? If not then, what else was happening at the same time?
Really, only 10%, thats much smaller than I imagined. Doesn't seem a particularly challenging target to me given the right incentives, which surely a...
... but suspicious it correlates with it getting shaded. 11C isnt particularly surprising. Hopefully its white in colour, if it were black it could ...
On other threads people complain about gurgling, which is due to dissolved air coming out of solution during the first couple of weeks. It took nearl...
A header (or low loss header - LLH) can be identified because flow from HP and flow to emitters and return from emitters and return to HP al...
Weird that the Mitsubishi engineer says no. My (vaillant) sensor was specifically placed by my installer somewhere in permanent shade, with no chance...
- 26 Forums
- 2,275 Topics
- 50.9 K Posts
- 138 Online
- 5,936 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Testing new controls/monitoring for Midea Clone ASHP
It has it's uses and there is no way I could have set t...
By benson , 39 minutes ago
-
Samsung Gen6 and Havenwise ........
I sourced the Wi-Fi unit (City Plumbing - £122 with 15%...
By Lenny , 58 minutes ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Definitely. 8C DT is higher than the default design DT...
By JamesPa , 3 hours ago
-
@jamespa Thanks again for your reassurance. Rob
By Ubert767 , 8 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
Thanks for the suggestion, but farmhouse is grade 2 lis...
By paultheheating , 10 hours ago
-
RE: My DIY Heat Pump installation
This is very kind. However software is not really my ...
By Polar bear , 15 hours ago
-
RE: Request for feedback on where we're at with our quest to get an ASHP or ideas.
thanks, heatpunk looks great, being able to do the calc...
By giryan , 1 day ago
-
RE: Is Your House Warmer Upstairs Than Downstairs?
Why arent you expecting them to make much difference. ...
By JamesPa , 1 day ago
-
@toodles sounds good. I started with cosy but then plug...
By Eliuccio , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It has been just over a year since we changed over to a...
By npru , 1 day ago
-
RE: Finding a Thermostatic Shower Valve That Works with Heat Pump Systems
@morgan I should just have written ‘Mea Culpa’ shouldn’...
By Toodles , 1 day ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
'We learn from history that we do not learn from histor...
By Lawrence Leask FInstR , 1 day ago
-
Mitsubishi Ecodan FTC7 Legionella date set
I can set the number of days between Legionella cycles ...
By DRB01 , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
@treewizard Yes, I like the extra facilities that NetZe...
By Toodles , 2 days ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk downstairs rads are less prone to airlocks, you ...
By AgentGeorge , 2 days ago
-
RE: My Octopus Cosy 6 Heat Pump Journey: From Quote to Completion
@editor thanks for highlighting my name. Yes I did get ...
By Chansug , 2 days ago
-
RE: balancing radiators with a mixture of different size pipework and a few undersize rads.
@editor Thanks for your input Mars. No I think the comm...
By baxtDave , 2 days ago
-
RE: Rate the quality of your heat pump design and installation
We’re looking to expand our list of recommended list of...
By Mars , 2 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Along with the right workers, they can’t b...
By Toodles , 2 days ago