Again thanks. Noted and safety issues are fair enough. The disappointment is (a) the extra CU and more particularly (b) the need to d...
Thanks Ah, so that places the 'off grid' port of the inverter between grid and load so protecting the grid. However it does introduce another co...
As I mentioned early on the cost of supplying and fitting a few rads is negligible. It certainly shouldn't come to legal proceedings if this is the b...
Thanks for the update. As you say you are now piggy in the middle. Its sometimes said that legal cases are won by those with the best filing syste...
@batpred, @transparent thanks Since the inverter isn't between the mains and the CU, does this need an (automatic?) cut out device that ...
Thanks all for the help, this seems to be nearly as complex as heating! My current thought process, and the remaining questions, are this: ...
I hadn't spotted that there were two pumps in the UFH (well spotted!) but I had recognised the risk that the upstairs rads weren't getting enough wate...
Never assume it makes an ass of u and me! You need the return temp to be lower than about 55 for a boiler to condense. If you start of with a FT of ...
Before I answer your specific questions just one more thing to highlight. The upstairs rads may well be big enough, but because your heatmiser is (pr...
The costs, if any, are not that great - see my calculation above and comment about (non-) condensing boilers. When I abandoned setback and turned my...
By 'no recovery penalty' I mean no efficiency penalty because it has to work harder to supply the extra energy needed to replace the energy lost durin...
This topic will run and run for sure The misunderstanding many suffer from (and the controls industry almost actively encourage this misunderstandin...
- 26 Forums
- 2,396 Topics
- 54.3 K Posts
- 359 Online
- 6,077 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Recommended home battery inverters + regulatory matters - help requested
Again thanks. Noted and safety issues a...
By JamesPa , 4 minutes ago
-
RE: Free Ecoheat Heat Pump Install
@deltona Yes older houses are problematic like that, bu...
By bontwoody , 12 minutes ago
-
RE: Radiator sizing sanity check
As I mentioned early on the cost of supplying and fitti...
By JamesPa , 3 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
I hadn't spotted that there were two pumps in the UFH (...
By JamesPa , 5 hours ago
-
RE: Setback savings - fact or fiction?
Never assume it makes an ass of u and me! You need the...
By JamesPa , 5 hours ago
-
RE: New Mitsubishi Ecodan 11.2kW installation - L9 errors and maybe more
Before I answer your specific questions just one more t...
By JamesPa , 5 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@agentgeorge Fortunately the one thing that you *won't*...
By dr_dongle , 5 hours ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@chandykris Thank you for your detailed response.It is ...
By Wally , 6 hours ago
-
RE: Electricity price predictions
Great point, one of the key ones in my chat with Octopu...
By Batpred , 15 hours ago
-
RE: Running from backup generaor in powercut?
Definitely and professionals sometimes miss it. I had...
By Batpred , 16 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Let me point out that there are many Chinese suppliers ...
By Transparent , 20 hours ago
-
RE: Weather compensation- why you should use it
@majordennisbloodnok — The Two Ronnies Mastermind sketc...
By cathodeRay , 20 hours ago
-
Just realised that this image of the cylinder cupboard ...
By Sheriff Fatman , 24 hours ago
-
RE: Rodents! A word of warning for heat pump owners
Two thoughts: 1: Let's ask @david-s if Primary Pro in...
By Transparent , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
In the diagram below, I describe my understanding of th...
By Batpred , 1 day ago
-
I need to have a look out for it. I know IBM feeds some...
By Batpred , 1 day ago
-
-
RE: Daikin Atherma ASHP Cycling 6 Times an Hour?
Thanks for your reply. Yes that's a good idea to try a...
By John Marshall , 1 day ago
-
RE: Hot water heating in parallel with space heating
An external heat exchanger would need a pump which woul...
By bontwoody , 1 day ago
-
RE: Gen 6 Samsung ASHP losing 20C of DHW in 60 min directly after generation
@ecobaker Thanks for this. I've had it in both slots. ...
By andbeck , 2 days ago