Reply
RE: Hot water heating in parallel with space heating

Its not really a downside of ASHPs, its a downside of using weather compensation. Boilers with WC have exactly the same limitation. Other than t...

2 minutes ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

The Sunny boy is old enough that it should be considered dumb for all practical purposes. It limits its own output to 16A (measured at its own output...

6 minutes ago
Reply
RE: Advice for a novice on Mitsubishi Ecodan 6kW

Doubtless its possible but Im not currently sure its necessary or even desirable. You have plenty of kit much of which is unnecessary and unhelpful, ...

15 hours ago
Reply
RE: Heat pump not reaching flow temperature

That doesn't make much sense as it should alter the flow temp, that's what WC is. 0 and 15 are presumably the outside temps, what are the correspond...

16 hours ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

It does but it almost all applies to boiler systems and I wish I had understood when I had a boiler as much as I understand now. Just before I replac...

17 hours ago
Reply
RE: ASHP Energy Consumption: Aira 12kW heat pump

Seriously? So 'our heat pumps just work, we don't know how, but trust us they do'. That sounds like a red flag of the highest order! No sorry tha...

18 hours ago
Reply
RE: Ecodan with FTC7 - True Weather Compensation

Some data is definitely useful. I ordered the internet connection for my Vaillant heat pump and use Home assistant to pick up some basic data because...

18 hours ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

So theres a problem for starters. This means that the FT flatlines at -2 which means that, when its <-2 it isnt high enough to deliver the energy ...

18 hours ago
Reply
RE: ASHP Energy Consumption: Aira 12kW heat pump

That seems high. Do you know what your WC settings are (even if you cant change them and even roughly?)  

18 hours ago
Reply
RE: Ecodan with FTC7 - True Weather Compensation

Very much agree with this! Sometimes the way to get things to operate in pure WC mode is to set the curve on the controller, then just turn all the ...

18 hours ago
Reply
RE: ASHP Energy Consumption: Aira 12kW heat pump

Thats sensible then   Most heat pumps seem to limit adjustment of the WC settings to installer mode, although some do expose something to ...

19 hours ago
Reply
RE: Recommended home battery inverters + regulatory matters - help requested

Fair enough and Im not trying to circumvent regulation, I was just checking that I understood the underlying cause for your comment and that I hadn't ...

19 hours ago