I sat through peter's youtube, this appears to be the method he's using. a better version of what I said to monitor the fossil fuel burn - using regre...
that graph is awful. even ignoring the ones where the installer estimate is zero, it's awful. could you please check that link reference? I wanted to ...
I think what one really needs to get this empirical "heat pump size" is for the house to be run with the fossil based heating reconfigured as close t...
@derek-m but an AC system has the same big grey box with a fan that makes noise on the outside of the premises , which is very difficult to distinguis...
@cashback would you mind me asking what "AC" option are you looking at? I already have the ASHP and would like to put cooling-capable chilled water ...
@sunandair apologies, one sometimes assumes a certain level of technical knowledge. The flow rate cannot be anything other than the same because its t...
I think we went through the "what can puts people off heat pumps" in another thread and came to a reasonable consensus capital cost (potentially)...
not sure what you mean by installer error, but flow rate as a volume per unit time doesn't change if your pipe gets bigger or smaller as you go along ...
@derek-m don't go there. A2A would have not been an easy piece of engineering in my house and no point discussing... in any case, in my case its good ...
@jamespa yes definitely by person and property. I read cathoderays write-up and the subsequent 6 pages of discussion and thought that might well be at...
just putting something in here that relates back to the discussion several pages back (sorry folks, been busy on other things) with some fascinating i...
@tim441 I just RTFM for your inverter. It has Ethernet as standard and wifi as an option. reasonable assumption is that the wifi option is not there ....
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 317 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
RE: ASHP sizing - value of Heat Transfer Coefficient
Sorry, but I cant see what the point of this is unless ...
By JamesPa , 4 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
TC Thermostatic Radiator Valve TRV Plastic Decorators S...
By Toodles , 7 hours ago
-
RE: Ecodan unable to hit legionella target temp - what's the consensus?
UPDATE: Thanks everyone who commened with suggestions h...
By 9jwr9 , 12 hours ago
-
-
How long will your energy contract last?
Some heat pump tariffs don’t run as long as a heat pu...
By Toodles , 2 days ago
-
@morgan They are unsupervised these days, can’t get the...
By Toodles , 2 days ago
-
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 4 days ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 4 days ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 4 days ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 4 days ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 4 days ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 4 days ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 4 days ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 4 days ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 4 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 4 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 4 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 5 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 5 days ago