@anca1808 I'd certainly backup the suggestion from @rhh2348 to check the consumption as measured by the unit - I know it is the main culprit in your h...
Thanks @abernyte - I remember seeing this video before, the technicalities are still beyond me but the general idea is useful to understand. Like...
@clockworks Looking at your flow temperature graphs, the rise before the pump stops is not particularly big. You could try this: Under Operation set...
The default setting is that the DHW is always 'on' but actually runs when the tank temperature drops below the max temp drop value. To force the DHW t...
"cycling is bad" - cycling can either indicate the inevitable result of the heat demand falling below the heat output of the pump or it can be a failu...
For clarity: The only reference to system volume I can find in the documentation I have relating to my EcoDan refers to the space heating circuit. The...
@alsocold123456 Only the primary circuit runs during the defrost cycle so shouldn't be taking heat out of the water sitting in the secondary heating ...
Amps - yes, you did say. Not the most useful measure to have graphed though!To your examples:Lets say 34 is the temperature at which the radiators to ...
I think this might be a different set of parameters for the user to interact with than the typical uk/european ones. That lower green line I commented...
As someone with an over-sized HP and the lower level of performance this entails for much of the year this strategy has a lot of appeal! I have a good...
I find the graphs somewhat hard to reconcile against the references to 31 or 32 @ 3° ambient as in both the flow temperature seems to be targeted at t...
Have you checked the pump speed in the settings menu for the HW cycle? And maybe check the flow rate while the HW cycle is running. The defrost cycle ...
- 22 Forums
- 2,021 Topics
- 44.1 K Posts
- 63 Online
- 3,193 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
Very much agree. I think OP is over-concerned about th...
By JamesPa , 2 hours ago
-
RE: Performance of Heat Pumps in Mild Weather
'and thus its capacity' assumes that output is a linear...
By JamesPa , 2 hours ago
-
Just an update on the responses received by Smart Heati...
By Eliuccio , 6 hours ago
-
RE: Is your gut better than Math
By SUNandAIR , 7 hours ago
-
@sandman1600 I’ve been following this thread and althou...
By bontwoody , 8 hours ago
-
RE: Would You Find Value in a Premium Installer-Supported Forum?
We are very pleased to announce that Brendon Uys (@heac...
By Mars , 9 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk Please feel free to post any proposals for com...
By JamesPa , 10 hours ago
-
RE: Ecodan 11.2kw Wireless thermostat drop outs
@skyecraig I've had our FTC7 wireless thermostat lose...
By RobS , 19 hours ago
-
RE: Signenergy AI Mode - How long does it take to learn a usage pattern?
I am definitely interested in this as I am considering ...
By Grantmethestrength , 1 day ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Hitachi Yutaki SCombi Heat Pump(Indoor Unit ) RWD-3.0RW...
By trebor12345 , 1 day ago
-
RE: Jokes and fun posts about heat pumps and renewables
ми не граємо в карти
By Transparent , 1 day ago
-
RE: Pressure Drop in primary circuit
Nick from Samsung has called me back . He has sa...
By ohdearism , 1 day ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
@adamk not sure I want to mess with the lockshields I a...
By jeegnesh , 1 day ago
-
RE: Hitachi Yutaki SCombi Heat Pump - Thermal Off's
Thanks for your help.
By trebor12345 , 2 days ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
Sorry to hear this is not yet fixed but please do keep ...
By JamesPa , 2 days ago
-
RE: What happens when the outside temperature exceeds the upper WC point?
The focus of this week’s podcast recording is on “Heat ...
By Mars , 3 days ago
-
RE: How many compressor starts per year
@gc61 Less that one start per hour is very good, our pu...
By MikeF , 3 days ago
-
@transparent ,thanks for the reply,I'm just wondering h...
By Browntrout , 3 days ago
-
RE: Opinions please on me putting a 2.5kW roof mounted turbine on my garage - am I mad?
You might want to have a look at some of the posts here...
By IRMartini , 3 days ago
Most Active This Week
# | Name | kWhs |
---|---|---|
1 | JamesPa | 214 |
2 | Mars | 123 |
3 | Toodles | 103 |
4 | AdamK | 98 |
5 | ohdearism | 88 |
6 | trebor12345 | 87 |
7 | Transparent | 77 |
8 | Gary | 76 |
9 | SUNandAIR | 70 |
10 | rhh2348 | 70 |