Last seen: Mar 17, 2025
May be, but also be the author know what he down. I dont know so much about this.We will see, I looked in Visual Studio. There are about 3600 lines.
Sorry, here is the link again
The Modbus register 135 module temperature feedback is not marked as a measured value, probably calculated. It is displayed in operating parameters 9/...
Ok, found this interesting notice in the text: "Der Zugriff auf die Parameter oder Änderungen sind nur qualifiziertem Servicepersonal gestattet, das...
You can find the description here (open in new tab), the modbus part starts on page 174, also alarms, password protected device parameters and service...
I received a technical documentation for a Midea clone with the description of the Modbus with the number, meaning and description in German. 147 regi...
@cathodeRay Please excuse misinterpreting your flowing diagram. In the Kaisai KHC08 is an electronical pump APM25-9-130 by Shimge working.
The shown flow is really very constant and poor also. Looks like the pump is not able to change the flow. Especially for dhw heating it could be not e...
The electricity meter is a Schelinger SL03A 10A(100A) Class1/B without modbus, only kontakt output 400counts/kWh, the output is not used. I looked not...
@cathodeRay Thanks for your much work getting the data of the pump. Last year I installed mechanical and electrical a midea clone named Kaisai with ...
Thanks for the information, I´m reading here some month and know this thread. HA is unknown for me, but I got a mini pc for collecting data and more. ...
Good day, living in the region of Hannover, found this forum searching for midea heatpumps, because bought a midea clone named Kaisai KHC08 from DK ...
- 26 Forums
 - 2,265 Topics
 - 50.6 K Posts
 - 358 Online
 - 5,924 Members
 
Join Us!
Podcast Picks
Latest Posts
- 
                        
RE: Oil Boiler & Heat Pump Hybrid System
thanks for your reply, tried to explain that tenants fo...
By paultheheating , 1 hour ago
 - 
                        
RE: Help me keep the faith with my air source heat pump installation
@jamespa I contacted the installer and asked them to ba...
By AdamK , 6 hours ago
 - 
                        
RE: UFH downstairs and radiators upstairs balancing question
@walnut-tree-cottage My bad, sorry I transpose while tr...
By ASHP-BOBBA , 7 hours ago
 - 
                        
RE: Who has a V2G EV installation
They certainly look stylish! But it seems that Ander...
By Batpred , 8 hours ago
 - 
                        
                                RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
And if MCS don’t have one on record that’s an issue bec...
By Mars , 8 hours ago
 - 
                        
                                RE: My DIY Heat Pump installation
@polar-bear, I take my hat off to you. I wish I had the...
By Mars , 8 hours ago
 - 
                        
                                RE: Electricity price predictions
One persons view In sync with the Nesta figures s...
By Jeff , 10 hours ago
 - 
                        
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
Ok so that seems to be the key point namely only mcs ca...
By JamesPa , 12 hours ago
 - 
                        
RE: One flow valve appears to be duff
You might want to consider the following common faults:...
By IaAck , 20 hours ago
 - 
                        
                                RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
We are on the Intelligent Octopus Go tariff. We instal...
By GrahamF , 22 hours ago
 - 
                        
RE: New build installation query
@paullacey While the others wait for more info do you m...
By ASHP-BOBBA , 1 day ago
 - 
                        
                                RE: British Gas Heat Pump Installation Complaint
@bgno, the other consideration for legionella cycles ar...
By Mars , 2 days ago
 - 
                        
                                @old_scientist I dont monitor the tank temperature but ...
By bontwoody , 2 days ago
 - 
                        
                                RE: Say hello and introduce yourself
Hello @paultheheating - I'm a rural Moderator! What's...
By Transparent , 2 days ago
 - 
                        
RE: What valves to replace radbots?
Yes. Radbots just replace TRV heads. TRV heads push t...
By JamesPa , 2 days ago
 - 
                        
RE: When will fusion be producing energy?
I am thinking of the case where AI was able to distingu...
By Batpred , 2 days ago
 - 
                        
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Very definitely. I think the market has changed a bit...
By JamesPa , 3 days ago
 - 
                        
                                RE: Buying large amp bidirectional RCD and RCBO
The following diagram is taken from the Meter Operator'...
By Transparent , 3 days ago
 