Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 13, 2025
@carpenterstation Yep that looks all normal, if you want to turn the heating off and leave the hot water on then you have to do it from the controller...
@robs Is this only in the newer controllers I don't have that option on my FTC5
[quote data-userid="6617" data-postid="44648" The DHW COP is the worst we've had yet strangely. And there were no big drains on the water yesterday. ...
Yes it’s really there to allow the heat pump to vary the flow temp above the set point if the room temp is significantly below the set point and then ...
On an Ecodan the std compensation curve mode only allows the flow temp to drift by 1 or 2C before it shuts off on auto adapt the allowable drift is pr...
32C is the lowest my system will go without cycling but at that flow temp the heat input is higher than the heat loss so the thermostat has to cut in ...
@robs What controller do you have I think mine is too old to have that, I don't recall ever seeing summer mode in the service menu.
Mitsubishi Ecodan just runs the same flow temp when it reaches the limit of the set curve. I am not aware of any way of telling the heat pump not t...
I suppose it depends on what battery you get I can only comment on the powerwall I had my first for 5 years before the inverter went and it was at 95%...
Yep exactly that
With a flow of 40C the dT for a 20C room temp is 20 it’s the difference in temp between flow and room. The output of a rad at dT 20 is 0.3 of its out...
- 26 Forums
- 2,661 Topics
- 62.3 K Posts
- 185 Online
- 7,066 Members
Join Us!
Directory
Degrees of Separation
Latest Posts
-
RE: Forum updates, announcements & issues
15,403,652 views as of a few minutes ago! Just over...
By Mars , 4 hours ago
-
RE: Outdoor Battery Solutions?
I hope that's not the case. PAS63100 has a number of ...
By Transparent , 1 day ago
-
RE: UPS to keep broadband and wifi available during power outages
In the strictest sense, it won't be the latter. The WAP...
By Majordennisbloodnok , 1 day ago
-
RE: Solar Schematic – Switching FiT Providers
@batpred Thanks. Im hoping the installer will provide o...
By bontwoody , 1 day ago
-
RE: Electricity price predictions
This could be a better thread for a discussion on elect...
By Batpred , 1 day ago
-
RE: How can I cool inverter and batteries during hot spells?
We had various types of insulation fit including ewi so...
By Batpred , 1 day ago
-
@etchedpixels I understand 80/20 rule, still HSE wou...
By Batpred , 1 day ago
-
Thanks, my impression is also that investing in a large...
By Batpred , 1 day ago
-
Sorry to hear about your installer going into liquidati...
By Batpred , 1 day ago
-
RE: The Reality Behind a Failed Heat Pump Installation – and an IWA Insurance Rejection
Thanks and that's very interesting...
By JamesPa , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
@jamespa they are based about 50 mile away so probably ...
By AdamK , 2 days ago
-
RE: Cooling with air to water heat pumps
@judith Agree, sometimes the simplest solutions just...
By Batpred , 2 days ago